期刊文献+

不同烧结温度的钛硅涂层对钴铬合金耐腐蚀性能的影响 被引量:3

Effects of Ti Si coatings with different sintering temperature on corrosion resistance of dental Co Cr alloy
下载PDF
导出
摘要 目的研究不同烧结温度下的钛硅(Ti Si)涂层对牙科软质钴铬合金(Co Cr)耐腐蚀性能的影响。方法选用临床常用的软质钴铬合金,制作成10mm×10mm×1mm规格的试件18件,将试件随机分成A、B、C 3组(n=6),在B、C组试件表面运用溶胶-凝胶法涂覆钛硅薄膜,分别设定900℃和1000℃的烧结温度。将A、B、C组试件分别浸于37℃乳酸/Na Cl溶液中7天,然后利用失重法计算材料的腐蚀速度,并运用等离子体发射光谱仪(ICP-AES)对溶液进行分析,以获得3种试件离子析出量的差异。结果 B、C 2组试件间腐蚀速度没有显著性差异(P>0.05),但都低于A组试件。离子析出量分析显示,B、C 2组试件的Co、Cr、Ni及总的离子析出量均少于A组试件(P<0.05),B组试件的Co、Cr、Si及总离子析出量显著高于C组试件(P<0.05)。结论钛硅涂层可显著提高软质钴铬合金的耐腐蚀性能,1000℃获得的钛硅涂层抗蚀性能优于900℃。 Objective To investigate the effects of titanium-silicon (TiSi) coatings with different sintering temperature on corrosion resistance of dental soft CoCr alloy. Methods The commonly used soft CoCr alloy was cast into 18 specimens of size 10mm × 10mm ×1 mm. These specimens were randomly divided into three groups (group A, B and C) (n=6). Then the specimens of group B and C were coated with TiSi on the surface by sol-gel method. The specimens of group B were sintered at 900℃, while the sintering temperature of group C specimens was 1000℃. The specimens of groupA, B and C were immersed in a lactic acid/NaCl solution at 37℃ for 7 days. The method of weight loss was used to analyze the corrosion rate. The solutions were analyzed with ICP-AES to determain the release of elements. Results In the analysis of weight loss method data, there were no significantly differences in corrosion rate between group B and C (P〉0.05). The corrosion rates of group B and C were lower than that of group A (P〈0.05). The specimens of group A released significantly more ions (Co, Cr, Ni,and total ions) compared with the group B and group C specimens (P〈0.05). The levels of Co, Cr, Si and total ions were higher in specimens of group B than that in group C (P〈0.05). Conclusion TiSi coating can significant improve the corrosion resistance of soft CoCr alloy. The TiSi coating sintered at the temperature of 1000℃ showed bettercorrosion performance than that of 900℃ .
作者 邹洁 胡滨
出处 《口腔材料器械杂志》 2015年第3期142-145,共4页 Chinese Journal of Dental Materials and Devices
关键词 钴铬合金 钛硅涂层 烧结温度 腐蚀 Co-Cr alloy TiSi coating Sintering temperature Corrosion
  • 相关文献

参考文献16

二级参考文献37

  • 1张富强,胡滨.溶胶-凝胶沉积金属钛方法的实验研究[J].中华口腔医学杂志,2004,39(4):306-308. 被引量:4
  • 2胡传昕 宋幼慧.涂层技术原理及应用[M].北京:化学工业出版社,2000..
  • 3Nascimento ML,Mueller WD,Carvalho AC,et al.Electrochemical characterization of cobalt-based alloys using themini-cell system[J].Dent Mater,2007,23(2):369-373.
  • 4Endo K,Ohno H,Matsuda K,et al.Electrochemical and surfacestudies on the passivity of a dental Pd-based casting alloy inalkaline sulphide solution[J].Corrosion Science,2003,45(7):1491-1504.
  • 5Huang HH.Surface characterization of passive film on NiCr-based dental casting alloys[J].Biomaterials,2003,24(9):1575-1582.
  • 6Wylie CM,Shelton RM,Fleming G,et al.Corrosion of nickel-based dental casting alloys[J].Dental Materials,2007,23(6):714-723.
  • 7Al-Mayouf,Al-Swayih,Al-Mobarak.Effect of potential on thecorrosion behavior of a new titanium alloy for dental implantapplications in fluoride media[J].Materials Corrosion,2004,55(2):88-94.
  • 8Nakagawa M,Matono Y,Matsuya S,et al.The effect of Pt and Pdalloying additions on the corrosion behavior of titanium influoride-containing environments[J].Biomaterials,2005,26(15):2239-2246.
  • 9Balamurugan A,Rebelo A,Kannan S,et al.Characterization andin vivo evaluation of sol-gel derived hydroxyapatite coatings onTi6Al4V substrates[J].J Biomed Mater Res B Appl Biomater,2007,81(2):441-447.
  • 10Roach MD, Wolan JT, Parsell DE, et al. Use of X-ray photoelectron spectroscopy and cyclic polarization to evaluate the corrosion behavior of six nickel-chromium alloys before and after porcelain-fused to metal firing. J Prosthet Dent, 2000, 84: 623-634.

共引文献23

同被引文献122

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部