期刊文献+

Correlation of the CT values of abdominal aorta,renal artery and renal cortex with its thickness on 64-MDCT contrast enhanced imagesCorrelation of the CT values of abdominal aorta,renal artery and renal cortex with its thickness on 64-MDCT contrast enhance

Correlation of the CT values of abdominal aorta,renal artery and renal cortex with its thickness on 64-MDCT contrast enhanced images
下载PDF
导出
摘要 Objective:To investigate the correlation of abdominal aorta CT value,renal artery CT value and renal cortex thickness with renal cortex CT value on contrast enhanced 64-slice CT images.Methods:96patients(50 men and 46women;16~74years)with normal kidney function,which was confirmed by kidney function test were enrolled in this study,including bilateral kidneys of 92cases and unilateral kidney of 4cases(total of 188kidneys;92left,96right).After intravenous(IV)injection of contrast agent the kidneys of the selected patients were scanned by MDCT.The scans were performed in arterial,venous and 3min delayed phases.All statistical analyses were performed by using IBM SPSS 20.0.Graphs were generated using Graph Pad Prism 5software.Quantitative data were presented as mean±standard deviation,while qualitative data were presented as frequency(%).P<0.05was considered to be statistically significant.Results:The mean renal cortex thickness was(5.19±0.81)mm in all kidneys.In the arterial phase,a statistically significant positive correlation between renal cortex CT values and abdominal aortic CT values was showed(r=0.584;P<0.001).A statistically significant positive correlation between renal cortex CT values and renal cortex thickness was demonstrated(r=0.533,P<0.0001).Likewise,there was a positive correlation between renal cortex CT value and renal artery CT values(r=0.43,P<0.001).Conclusion:It is a promising approach to assess the individual kidney function by measuring abdominal aorta CT value,renal artery CT value,renal cortex CT value and renal cortex thickness using contrast MDCT. Objective:To investigate the correlation of abdominal aorta CT value,renal artery CT value and renal cor-tex thickness with renal cortex CT value on contrast enhanced 64-slice CT images.Methods:96 patients (50 men and 46 women;16-74 years)with normal kidney function,which was confirmed by kidney function test were enrolled in this stud-y,including bilateral kidneys of 92 cases and unilateral kidney of 4 cases (total of 188 kidneys;92 left,96 right).After intra-venous (IV)injection of contrast agent the kidneys of the selected patients were scanned by MDCT.The scans were per-formed in arterial,venous and 3min delayed phases.All statistical analyses were performed by using IBM SPSS 20.0.Graphs were generated using Graph Pad Prism 5 software.Quantitative data were presented as mean ±standard deviation,while qualitative data were presented as frequency (%).P〈0.05 was considered to be statistically significant.Results:The mean renal cortex thickness was (5.19±0.81)mm in all kidneys.In the arterial phase,a statistically significant positive correla-tion between renal cortex CT values and abdominal aortic CT values was showed (r= 0.584;P〈0.001).A statistically sig-nificant positive correlation between renal cortex CT values and renal cortex thickness was demonstrated (r= 0.533,P〈0.0001).Likewise,there was a positive correlation between renal cortex CT value and renal artery CT values (r= 0.43,P〈0.001).Conclusion:It is a promising approach to assess the individual kidney function by measuring abdominal aorta CT value,renal artery CT value,renal cortex CT value and renal cortex thickness using contrast MDCT.
出处 《放射学实践》 北大核心 2015年第8期849-854,共6页 Radiologic Practice
关键词 Tomography X-ray COMPUTED CONTRAST agents Kidney function testsl ABDOMINAL AORTA Renal cortex Tomography, X-ray computed Contrast agents Kidney function testsl Abdominal aorta Renal cortex
  • 相关文献

参考文献35

  • 1Morrisroe SN. Su RR. Bae KT. et al. Differential kidney function estimation using computerized tomography based renal parenchymal volume measurement[J].J Urol. 2010 .183( 6): 2289-2293.
  • 2Hackstein N. BauerJ. Hauck EW. et al. Measuring single-kidney glomerular filtration rate on single-detector helical CT using a two-point Patlak plot technique in patients with increased interstitial space[J]. AJR.2003.181(l) :147-156.
  • 3Daghini E.Juillard L. HaasJA. et al. Comparison of mathematic models for assessment of glomerular filtration rate with electronbeam CT in pigs[J]. Radiology.2007.242(2) :417-424.
  • 4O'Dell-Anderson Kj v Twardock R.GrimmJB.et al. Determination of glomerular filtration rate in dogs using contrast-enhanced computed tomography].}"]. Vet Radiol Ultrasound. 2006.47 (2) : 127- 135.
  • 5Rubin GD. Alfrey EJ. Dake MD. et al. Assessment of living renal donors with spiral CT[J]. Radiology.1995.195(2) :457-462.
  • 6Cochran ST. Krasny RM.Danovitch GM.et al. Helical CT angiography for examination of living renal donors[J]. AJR. 1997.168 (6): 1569-1573.
  • 7PlattJF. EllisJH ? Korobkin M. et al. Helical CT evaluation of potential kidney donors-findings in 154 subjects[J]. AJR.1997 .169 (5): 1325-1330.
  • 8Smith P'Av Ra tner LE.Lynch FC.et al. Role of CT angiography in the preoperative evaluation for laparoscopic nephrectomy[J]. Radiographics, 1998 , 18 (6) : 589-60 l.
  • 9Pozniak MA.Balison DJ. LeeJr FT. et al. CT angiography of potential renal transplant donors [J]. Radiographies. 1995, IS (3): 565-587.
  • 10Del PizzoJ J , Sklar GN, You-CheongJW. et al. Helical computerized tomography arteriography for evaluation of live renal donors undergoing laparoscopic nephrectomy[J].J Urol. 1999, 162(1): 31-34.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部