期刊文献+

早期乳腺癌MRI弥散加权成像与Ki-67表达的相关性研究 被引量:4

Correlation Study on MR DWI and Ki-67 Expression in Early Breast Cancer
下载PDF
导出
摘要 目的探讨早期乳腺癌在不同b值下的DWI成像特点及其ADC值改变、与Ki-67表达的相关性。方法对35例早期乳腺癌患者行MRI DWI检查,其b值分别取为500s/mm2、800s/mm2、1000s/mm2,分别测定癌灶在不同b值下扫描后的ADC均值,分析其DWI信号特点,比较其ADC值的差异性,并与术后病理Ki-67表达的相关性进行统计学分析。结果所有病例均为早期浸润性导管癌,瘤灶在DWI上均呈明显高信号。b值500s/mm2组(b-500组)与b值800s/mm2组(b-800组)、b-500组与b值1000s/mm2组(b-1000组)间ADC值存在统计学显著性差异(P值<0.05);而b-800组与b-1000组的ADC均值间无统计学显著性差异(P值>0.05)。b-500组、b-800组、b-1000组ADC均值分别为1.1416×10-3mm2/s、0.9258×10-3mm2/s、0.8668×10-3mm2/s。不同b值扫描后所测得瘤灶的三组ADC均值与Ki-67表达间的相关性均无统计学显著性差异(P>0.05)。结论早期乳腺癌不同b值下扫描所测得的ADC值间存在一定的差异性,选择b值为800s/mm2时扫描较为合理。当ADC值低于0.9258×10-3mm2/s时提示早期乳腺癌的可能。早期乳腺癌的ADC值与Ki-67表达之间无明显相关性。 Objective To investigate the features of MR DWI with different b values, changes of ADC value, correlation of ADC value with Ki-67 expression in early breast cancer. Methods 35 patients with early breast cancer underwent MR DWI scanning with different b values, including 500s/mm^2、800s/mm^2、1000s/mm^2.The ADC values of the tumor lesions were measured after scanning with different b values. The DWI signal features of the tumor lesions were analyzed. The differences of the ADC Values were statistically compared, and the correlations of ADC values of the lesions with Ki-67 expressions were statistically analyzed. Results All of the patients were early breast invasive ductal carcinoma. All of the tumor lesions showed obviously high signal in DWI. There were statistically significant differences(P〈0.05) between the mean values of the group of b-value 500s/mm^2 (group of b-500) with group of b-value 800s/mm^2 (group of b-800), Group of b-500 with group of b-value 1000s/mm^2 (group of b-1000),respectively. However, there was no statistically significant difference(P〉0.05) between the group of b-800 and group of b-1000.The mean ADC values were 1.1416×10^-3mm^2/s(group of b-500), 0.9258×10^-3mm^2/s (group of b-800), 0.8668×10^-3mm^2/s(group of b-1000),respectively. The correlations between the ADC values of the three different b-value groups and the Ki-67 expressions were not statistically different(P〉0.05). Conclusion There are certain differences between the ADC values measured after DWI scanning with different b values in early breast cancer. It is more suitable to select b-value 800s/mm^2 for DWI scanning in breast cancer. It is possible to diagnose early breast cancer when the ADC value is less than 0.9258×10^-3mm^2/s.The ADC value of early breast cancer was not obviously correlative with Ki-67 expression.
出处 《中国CT和MRI杂志》 2015年第9期72-74,F0002,共4页 Chinese Journal of CT and MRI
基金 2012年珠海市科技局立项 基金资助课题 项目编号2012D0401990011
关键词 早期乳腺癌 磁共振弥散加权成像 ADC值 KI-67表达 Early Breast Cancer MR-DWI ADC Value Ki-67 Expression
  • 相关文献

参考文献15

二级参考文献112

共引文献309

同被引文献39

引证文献4

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部