期刊文献+

ProTaper锉预备S形模拟根管偏移产生的连续观察

Continuous observation of canal transportation in S-shaped simulated root canal prepared by hand-used ProTaper
下载PDF
导出
摘要 目的连续观察在ProTaper各号锉成形S形树脂模拟根管中根管偏移的形成过程。方法选用15个S形树脂模拟根管分别用手用ProTaper的各号锉按使用说明书进行预备,采集并储存Sl、S2、Fl、F2和F3预备完后的根管图像。结果 ProTaper各号锉对根管弯曲的凹侧壁过度切削,而对弯曲凸侧壁仅Sl、S2号器械有切削。结论手用Pro-Taper锉预备S形树脂模拟根管,对根管内侧壁的切削非常不均匀。
出处 《全科口腔医学电子杂志》 2015年第4期122-123,共2页 Electronic Journal of General Stomatology
  • 相关文献

参考文献4

二级参考文献16

  • 1Sehirrmeister JF, Strohl C, Altenburger M J, et al. Shaping ability and safety of five different rotary nickel-titanium instruments compared with stainless steel hand instrumentation in simulated carved root canals [J]. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2006, 101(6):807-813.
  • 2Schafer E, Vlassis M. Comparative investigation of two rotary nickel -titanium instruments: ProTaper versus RaCe. Part 1. Shaping ability in simulated curved canals[J]. Int Endod J, 2004,37(4):229- 238.
  • 3Guelzow A, Stamn O, Martus P, et al. Comparative study of six rotary nickel-titanium systems and hand instrumentation for root canal preparation [J]. Int Endod J,2005,38(10):743-752.
  • 4Calberson FL, Deroose CA, Hommez GM, et al. Shaping ability of ProTaper Nickel-Titanium files in simulated resin root canals [J]. Int Endod J,2004,37(9) :613-623.
  • 5Alapati SB, Brantley WA, Svec TA, et al. Proposed role of embedded dentine chips for the clinical failure of nickel-titanium rotary instruments [J]. J Ended, 2004, 30(5):339-341.
  • 6Tompson SA, Dummer PMH. Shaping ability of Mity Roto 360° and Naviflex rotary nickel-titanium instruments in simulated root canals. Part 2 [J]. J Endod 1998,24(2) :135-142.
  • 7Yoshimine Y, Ono M, Akamine A. The shaping effects of three NiTi rotary instruments in simulated S-shaped canals [J]. J Endod, 2005, 31(5):373-375.
  • 8Di Fiore PM, Genov KA, Komaroff E, et al. Nickel-titanium rotary instrument fracture: a clinical practice assessment [J]. Int Endod J, 2006, 39(9) :700 -708.
  • 9Schafer E, Vlassis M. Comparative investigation of two rotary nickel-titanium instruments: ProTaper versus RaCe. Part 2.Cleaning effectiveness and shaping ability in severely curved root canals of extracted teeth [J]. Int Endod J, 2004,37(2):239-248.
  • 10Schafer E,V assis M.Comparative investigation of two rotary nickel-titanium instruments:ProTaper versius RaCe [J].Int Endod J,2004,37(4):229~238

共引文献3