摘要
简述隧道内发生事故灾害的严重性,研究了新型蓄光反光材料在隧道中的作用机理,针对隧道停电和火灾两种事故灾害,通过对蓄光反光材料余辉亮度测试和Dialux亮度计算软件的仿真计算,分析和模拟了新型蓄光反光材料在两种事故灾害发生后的作用效果。
The severity of accident disaster happed in tunnels is described in general, and the mechanism of new type light-storing and emitting materials adopted in tunnel is studied. Regarding to the power failure and fire disaster in tunnel, and through measure of afterglow brightness of the materials and simulation by means of Dialux brightness calculation software, the effect of the new type light-storing and emitting materials are analyzed and simulated.
出处
《公路》
北大核心
2015年第8期250-254,共5页
Highway
基金
交通运输部应用基础研究项目
项目编号2014319814260
关键词
新型蓄光反光材料
隧道事故灾害
余辉亮度
Dialux亮度计算软件
应急照明
new type light-storing and emitting material
accident and disaster in tunnel
afterglow brightness
Dialux brightness calculation software
emergency lighting