期刊文献+

准分子激光治疗仪的设计与研制

The Design and Manufacture of Excimer Laser Refractive Surgery System
下载PDF
导出
摘要 准分子激光治疗仪包括波长193nm的准分子激光器及激光工作气体氟化氩(Ar F)、光路传输系统、激光控制系统、扫描系统、眼跟踪系统、照明系统及人机交互系统等。通过人机交互系统设置手术参数,生成手术方案。系统通过控制扫描电机实现角膜组织的切削。经临床试验证明,该准分子激光治疗仪治疗效果稳定、安全和有效。 Excimer laser refractive surgery system consist of excimer laser with a wavelength of 193 nm,argon lfuoride (ARF), optical transmission system, laser control system, scanning system, eye tracking system, illuminating system and human-computer interaction system. To set up the operation parameters, the system can generate automaticaly the operation scheme. The system control the scanning motor to realize the corneal tissue ablation. The clinical trial had carried out to verify stability, safety and effectiveness of the excimer laser refractive surgery system.
出处 《中国医疗器械信息》 2015年第7期55-58,共4页 China Medical Device Information
关键词 准分子激光 屈光不正 眼跟踪 飞点扫描 excimer laser refractive error eye tracking lfying-spot scanning
  • 相关文献

参考文献3

二级参考文献15

  • 1Zhang Jingao, Ma Zhiming, Liu Jingmei. Refractive EyeSurgery[M].Zheng zhou:Henan Scientific and Technical Publsihing House,1996.(in Chinese)
  • 2Weigelt G.Modified speckle inteferometry:speckle masking[J].Opt Common,1997,21:55.
  • 3Lohmann A W,Weigelt G P,Wirnitzer B.Speckle masking in astronomy trible correlation theory and application[J].Appl Opt,1983,22:4028-4037.
  • 4Bartelt H,Lohmann A W,Wirnitzer B.Phase and amplitude recovery from bispectra[J].Appl Opt,1984,23:3121-3129.
  • 5CHEONG Wai-fang.Areview of the optical properties of biological tissue[J].IEEE Journal of Quantum Electronics,1990,26(12):2166-2185.
  • 6Condon PI, O'Keefe M, Binder PS. Long-term results of laser in situ keratomileusis for high myopia: risk for ectasia[J]. J Cataract Refract Surg,2007,33:583-590.
  • 7Zhang F, Deng S, Guo N, et al. Confocal comparison of corneal nerve regeneration and keratocyte reaction between FS:LASIK, OUP-SBK, and conventional LASIK[J]. Invest Ophthalmol Vis Sci, 2012,53 : 5536-5544.
  • 8Slade SG, Durrie DS, Binder PS. A prospective, contralateral eye study comparing thin-flap LASIK (sub-Bowman keratomileusis) with photorefractive keratectomy[J]. Ophthalmology,2009,116: 1075-1082.
  • 9Han DC, Chen J, Htoon HM, et al. Comparison of outcomes of conventional WaveLight Allegretto Wave and Technolas excimer lasers in myopic laser in situ keratomileusis[J]. Clin Ophthalmol, 2012,6 : 1159-1168.
  • 10Gazieva L, Beer MH, Nielsen K, et al. A retrospective comparison of efficacy and safety of 680 consecutive lasik treatments for high myopia performed with two generations of flying-spot excimer lasers[J]. Acta Ophthalmol,2011,89 : 729- 733.

共引文献2