将某玻璃企业的生产废水及办公楼、浴室的生活污水进行混合,收集处理后全部回用,处理工艺采用水解酸化—曝气生物滤池—超滤组合工艺。运行结果表明,出水水质可满足《工业循环冷却水处理设计规范》(GB50050—2007)中规定的再生水作为间冷开式系统补充水的水质指标要求,以及《城市污水再生利用城市杂用水水质》(GB/T 18920—2002)中城市绿化、道路清扫和冲厕的水质指标要求,实现了厂区污水零排放,年减少COD排放量12.41 t,年节水1.44×105 m3,实现了环境效益和经济效益的双羸。
After the plant wastewater and domestic sewage from bathroom and office in a glass company have been mixed and collected, they can all be reused. The treatment process is hydrolytic acidification-BAF-uhrafiltration. The results show that the effluent quality can meet the requirements for the water quality indexes of the treatment and design of reclaimed water as make-up water of indirect cooling and open system, stipulated for the Code for Design of Industrial Recirculating Cooling Water Treatment (GB 50050--2007), and the effluent quality can meet the requirements for urban greening, road sweeping and toilet flushing specified in the Reuse of Urban Recycling Water: Water Quality Standard for Urban Miscellaneous Water Consumption (GB/T 18920--2002), realizing the zero discharge of wastewater around the plant. COD discharge quantity can be reduced by 12.41 t/a, saving 1.44× 10^5 m^3 of water per year, and realizing an environmental and economic benefit win-win situation.