期刊文献+

铋-钨酸盐-罗丹明6G体系光度法测定痕量铋的研究 被引量:1

Study on the Spectrophotometric Method for the Determination of Bismuth with Bismuth-Tungstate-Rhodamine 6G System
下载PDF
导出
摘要 Bi(III)与钨酸盐及罗丹明6G 在硫酸介质中反应生成离子缔合物,该离子缔合物在550 nm 处有较强吸收,基于此现象,建立了一个测定痕量 Bi(III)的光度分析方法。该方法的线性范围为0.2-1.0μg /L,摩尔吸光系数为7.27×10^7 L·mol ^-1·cm^ -1,检出限(以3倍空白值的标准偏差除工作曲线的斜率计算)为0.035μg /L,而且常见离子基本上不干扰测定。将该方法用于自来水及环境水样中铋的测定,测定结果的相对标准偏差小于3.0%,加标回收率位于95-105%之间。 A spectrophotometric method for the determination of Bi(III)was developed based on the ion-associated reaction among bismuth(III),tungstate and butyl rhodamine 6G in H2 SO4 medium.The good linear relationship between the absorbance at 550 nm and the concentration of Bi(III)in the range of 0.2 -1.0 μg/L was obtained with the apparent molar absorptivity of 7.27 ×10^7 L·mol ^-1 ·cm^ -1 and limit of de-tection (obtained from 3σ/K.here,σis 3 times of the standard deviation of the blank value,and K is the slope of the working curve )of 0.035 μg/L.The method,which was not interfered by most of the common i-ons,could be used for the determination of bismuth in running water and environmental water samples.The relative standard deviation of the results obtained by this method was below 3.0%,and the recovery was in the range of 95 -105%.
出处 《云南化工》 CAS 2015年第4期26-30,共5页 Yunnan Chemical Technology
关键词 罗丹明6G 离子缔合物 光度法 bismuth rhodamine 6G ion-associated complex spectrophotometry