摘要 肝储备功能是评价肝脏正常生理活动的重要依据,动脉血氧饱和度是肝储备功能测量的重要中间变量,针对长时间连续无创血氧饱和度测量的要求,提出基于交直流分离的反射式血氧测量系统的设计方案。通过测量手指、耳尖等皮肤薄弱部位的反射式光电容积脉搏波,利用交直流信号分离处理技术,基于动脉血氧饱和度经验测量公式,实现长时间无创动脉血氧饱和度测量。交直流分离技术的使用能够有效的降低系统干扰和噪声的影响,优化血氧饱和度测量结果;经临床医疗对比实验检测,证明系统误差符合实际测量要求。 Liver reserve function is an important parameter for evaluation of the normal physiological activities of liver, oxygen saturation is an important intermediate variable of the liver reserve function measurement. This paper process a design for measuring the oxygen saturation based on reflectance method and AC/DC separation for the purpose of continuous measurement of blood oxygen saturation in non-invasive detection method. By measuring the reflective photoplethysmography (PPG) of the finger tip or ear tip, separating AC/DC signal to reduce the system noise and motion interference, aiming to optimize oxygen saturation measurement results;In contrast with clinical test and calibration, system measurement error meet the requirement.
出处 《传感技术学报》 CAS CSCD 北大核心 2015年第6期933-937,共5页 Chinese Journal of Sensors and Actuators
基金 2012年博士点基金课题项目-博导类(20120061110092)
关键词 光电技术 血氧饱和度 交直流分离 光电容积脉搏波 无创检测 photoelectric technology oxygen saturation ( SpO2 ) AC/DC signal separation photoplethysmography (PPG) non-invasive detection
  • 相关文献

参考文献12

二级参考文献95

共引文献121

同被引文献70

  • 1李刚,卢宗武,林凌.DDS芯片AD9854在脉搏波阻抗谱测量中的应用[J].传感技术学报,2007,20(11):2494-2498. 被引量:5
  • 2李文耀,王博亮,戴君伟.基于PIC单片机的脉搏血氧测量仪的研制[J].厦门大学学报(自然科学版),2005,44(4):507-510. 被引量:12
  • 3CUI Jian,GAO Shumei,SONG Yilin.Development ofsimultaneous monitoring system for non-invasive bloodpressure and blood oxygen saturation[C].2013 IEEE11th International Conference on Electronic Measurement& Instruments (ICEMI),Harbin: IEEE Press,2013:968-973.
  • 4KANO M,SATO Y,KANDA K,et al.Fabrication of reflectancepulse oximeter with ring-shaped photodiode[C].2013 IEEE International Conference on Systems,Man,and Cybernetics (SMC),Manchester:IEEE Press,2013:3771-3774.
  • 5VENEMA B,GEHRING H,MICHELSEN I,et al.Robustness,specificity,and reliability of an in-ear pulseoximetric sensor in surgical patients[J].IEEE Journal ofBiomedical and Health Informatics,2014,18(4):1178-1185.
  • 6LEE S,SHIN H,HAHM C.Effective PPG sensor placementfor reflected red and green light,and infraredwristband-type photoplethysmography[C].2016 18thInternational Conference on Advanced CommunicationTechnology (ICACT),Pyeongchang:IEEE Press,2016:556-558.
  • 7PATTERSON M S,CHANCE B,WILSON B C.Timeresolved reflectance and transmittance for the noninvasivemeasurement of tissue optical properties[J].Applied Optics,1989,28(12):2331-2336.
  • 8PANG G,MA C.A neo-reflective wrist pulse oximeter[J].IEEE Access,2014(2):1562-1567.
  • 9胡劲松,杨世锡,任达千.基于样条的振动信号局域均值分解方法[J].数据采集与处理,2009,24(1):82-86. 被引量:30
  • 10刘光达,郭维,朱平,白明明.基于容积波分析的血氧饱和度测量系统[J].激光与红外,2009,39(2):169-172. 被引量:32

引证文献12

二级引证文献56

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部