期刊文献+

光学相干断层扫描技术眼前节成像的应用探讨 被引量:2

Discussion on application of optical coherence tomography for anterior segment imaging
下载PDF
导出
摘要 通过无创性手段获得眼前节组织结构信息,对于眼科临床诊断及科研尤为重要。随着科技的进步,光学相干断层扫描技术(optical coherence tomography,OCT)在眼科临床及科研的应用已经得到广泛认可。目前不仅可以实现组织结构的精细成像,并可以进行对应的量化分析,为临床治疗的评估、随访观察提供不可替代的信息。 It is very important for ophthalmic clinical diagnosis and research to obtain anterior segment information by non-invasive means. With the progress of science and technology, the application of optical coherence tomography (OCT) on clinical practice and scientific research of ophthalmology has been widely accepted. It not only can achieve precise imaging of an organization structure, but also can do some quantitative analysis for the assessment of clinical treatment and follow-up as an irreplaceable information.
出处 《国际眼科杂志》 CAS 2015年第9期1567-1571,共5页 International Eye Science
关键词 光学相干断层扫描 前节 角膜 optical coherence tomography anterior segment cornea
  • 相关文献

参考文献57

  • 1Huang D,Swanson EA,Lin CP, et al. Optical coherence tomography. Science 1991; 254(5035):1178-1181.
  • 2Izatt JA, Hee MR, Swanson EA,et al. Micrometer-scale resolution imaging of the anterior eye in vivo with optical coherence tomography. Arch Ophthalmol 1994; 112(12):1584-1589.
  • 3Chong RS,Sakata LM,Narayanaswamy AK,et al. Relationship between intraocular pressure and angle configuration:an anterior segment OCT study. Invest Ophthalmol Vis Sci 2013; 54(3):1650-1655.
  • 4Huang G, Gonzalez E, Peng PH,et al. Anterior chamber depth, iridocorneal angle width, and intraocular pressure changes after phacoemulsification:narrow vs open iridocorneal angles. Arch Ophthalmol 2011; 129(10):1283-1290.
  • 5Kumar DA, Agarwal A, Prakash G,et al. Evaluation of intraocular lens tilt with anterior segment optical coherence tomography. Am J Ophthalmol 2011; 151(3):406-412.
  • 6Werner L, Michelson J, Ollerton A, et al. Anterior segment optical coherence tomography in the assessment of postoperative intraocular lens optic changes. J Cataract Refract Surg 2012; 38(6):1077-1085.
  • 7Wang X, Wu Q. Investigation of the human anterior segment in normal chinese subjects using a dual Scheimpflug analyzer. Ophthalmology 2012; 120(4):703-708.
  • 8Rufer F, Sander S, Klettner A,et al.Characterization of the thinnest point of the cornea compared with the central corneal thickness in normal subjects. Cornea 2009; 28(2):177-180.
  • 9Ambrosio R Jr, Alonso RS, Luz A,et al.Corneal-thickness spatial profile and corneal-volume distribution: tomographic indices to detect keratoconus. J Cataract Refract Surg 2006; 32(11):1851-1859.
  • 10Huang JY, Pekmezci M, Yaplee S,et al. Intra-examiner repeatability and agreement of corneal pachymetry map measurement by time-domain and Fourier-domain optical coherence tomography. Graefes Arch Clin Exp Ophthalmol 2010; 248(11):1647-1656.

同被引文献14

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部