期刊文献+

针刺手三里穴位动态超声显像 被引量:13

Dynamic ultrasound imaging of the acupuncture on the Shousanli points
下载PDF
导出
摘要 目的动态观察手三里穴位在针刺条件下的超声影像学解剖特征。方法选取健康志愿者15名,采用高频超声观察针灸针刺入受试者双侧手臂手三里穴后针尖的位置,以及针刺过程中与得气相关的解剖学结构。结果针刺15名受试者双侧手三里穴共30个穴位点均得气,针尖位置:桡侧腕伸肌13个,桡侧腕伸肌与旋后肌间筋膜9个,旋后肌浅层2个,旋后肌内筋膜4个,旋后肌深层1个,桡骨表面1个。28个(28/30,93.33%)针尖位于筋膜旁及筋膜集中处获得较强得气感、2个(2/30,6.67%)针尖位于较浅层即可获得较强得气感。高频超声可以清楚显示针尖点附近筋膜内的细小神经,二维声像图表现:桡神经深支沿着筋膜发出许多细小的分支,横断面声像图上呈筛孔样、回声较周围筋膜组织稍低。结论高频超声可以实时、动态、清楚地显示针刺点附近筋膜及筋膜内的细小神经分布,并可对针灸位置进行定量测定。 Objective To observe the anatomical characteristics of the Shousanli points in acupuncture by high-frequency ultrasound. Methods Fifteen participants received needling at two Shousanli points, high-frequency ultrasound was used to observe the position of needle tips when acupuncturing the Shousanli points, and the anatomical structures corresponding with "deqi" during acupuncture in 30 cases. Results All of the 15 volunteers with 30 Shousanli points got "deqi", the nee- dle tips position: 13 in The extensor carpi radialis muscle, 9 in the fascia between extensor carpi radialis muscle and supina- tion muscle, 2 in the shallow supinator muscle, 4 in the fascia between the shallow and the deep supinator muscle, 1 in the deep supinator muscle, 1 in the surface of radius. There were 28 (28/30, 93.33%) mainly in near fascia or where fascia concentrated when volunteers presented strong "deqi", and 2 (2/30, 6.67%) were in superficial structure when volunteers presented strong "deqi". High-frequency ultrasound can provide clear observation of the very small nerve distribution in fascia around the needle points in acupuncture. The ultrasound image showed many small branches of the deep branch of ra- dial nerve along the fascia, and the image of the small nerve on cross section was in mesh sample and the echo was slightly lower than fascia tissue around it. Conclusion High-frequency ultrasound can provide real-time, dynamic and accurate ob- servation of the fascia and the very small nerve distribution in fascia around the needle points in acupuncture, as well as quantitative measurement of the tip position.
出处 《中国介入影像与治疗学》 CSCD 北大核心 2015年第9期532-535,共4页 Chinese Journal of Interventional Imaging and Therapy
基金 国家杰出青年科学基金(81425014) 国家自然科学基金(81270021 81271598) 教育部科学技术研究重点项目([2012]76) 教育部新世纪优秀人才支持计划(NCET-13-1067) 重庆市杰出青年基金(cstc2013jcyjjq10004) 重庆市教委科学技术研究重点项目(KJ120328)
关键词 超声检查 手三里穴 筋膜组织 神经 Ultrasonography Shousanli points Fascia tissue Nerve
  • 相关文献

参考文献15

  • 1Umans H, Kessler J, de la Lama M, et al. Sonographic assessment of volar digital nerve injury in the context of penetrating trauma. AJR Am J Roentgenol, 2010,194(5):1310-1313.
  • 2Zheng YY, Wang LH, Krupka TM, et al. The feasibility of using high frequency ultrasound to assess nerve ending neuropathy in patients with diabetic foot. Eur J Radiol, 2013,82(3):512-517.
  • 3李杰.手三里穴的临床应用[J].光明中医,2009,24(3):499-500. 被引量:8
  • 4赵新宇,鄂占森,徐文中,陈敏,张颖,柳展梅,吕海霞.高频超声检查肘部桡神经[J].中国医学影像技术,2010,26(4):778-779. 被引量:7
  • 5单建林,姜恒,孙天胜,时述山.桡神经深支的体表定位及其临床意义[J].中国临床解剖学杂志,2004,22(4):347-349. 被引量:9
  • 6Park JE, Ryu YH, Liu Y, et al. A literature review of de qi in clinical studies. Acupunct Med, 2013,31(2):132-142.
  • 7刘斌(综述),张东友(审校).脑功能成像技术在针灸学中的研究进展[J].中国中西医结合影像学杂志,2009,7(2):125-128. 被引量:7
  • 8Park JJ, Akazawa M, Ahn J, et al. Acupuncture sensation during ultrasound guided acupuncture needling. Acupunct Med, 2011,29(4):257-265.
  • 9原林,白宇,黄泳,吴金鹏,王春雷,王军,杨春,戴景兴,沙鸥,姚大卫.经络的解剖学发现与筋膜学理论[J].上海针灸杂志,2011,30(1):1-5. 被引量:53
  • 10Konofagou EE, Langevin HM. Using ultrasound to understand acupuncture. IEEE Engineering in Medicine and Biology Magazine, 2005,24(2):41-46.

二级参考文献79

共引文献257

同被引文献232

引证文献13

二级引证文献47

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部