期刊文献+

国内外通风用空气过滤器的测试、分级及比照 被引量:12

Test,classification and comparison of foreign and domestic ventilating air filters
下载PDF
导出
摘要 简述了近些年国内外通风用空气过滤器主要测试方法的发展和相关标准的演变,介绍了作者提出的通风用空气过滤器分类曲线及国内外通风用空气过滤器的主要分级方法,给出了国内外通风用空气过滤器级别间的比照,供设计选用参考。 Introduces in briefly the development of testing methods of the air filter and the evaluation of related standards at home and abroad in recent years. Presents the classification curve proposed by the authors and the main classification methods for foreign and domestic ventilating air filters. Performs the comparison of different classifications at home and abroad, providing references for the design and selection of ventilating air filters.
出处 《暖通空调》 北大核心 2015年第8期53-61,共9页 Heating Ventilating & Air Conditioning
关键词 一般通风用空气过滤器 试验气溶胶 计重法 粒子计数计径法 计径过滤效率 最低效率报告值 分级 air filter for general ventilation, test aerosol, weight arrestance method, particle countingand sizing method, particle size removal efficiency, minimum efficiency reporting value (MERV),classification
  • 相关文献

参考文献19

  • 1涂有,周志坤,John Burnett,陈维田.香港住宅室内环境及污染暴露量研究[J].环境科学学报,2003,23(4):476-482. 被引量:6
  • 2Tu E Y, Chau C K, Tu G B. Evaluating the effectiveness of air po|lution abatement policy of Hong Kong[J~. Transactions of Tianjin University, 2007, 13(1).. 70-78.
  • 3ASHRAE. ANSI/ASHRAE Standard 52. 1-1992 Gravimetric and dust-sPot procedures for testing air- cleaning devices used in general ventilation for removing particulate matter[S]. Atlanta: ASHRAE Inc, 19~2.
  • 4European Committee for Standardization. EN 779: 1993 Particulate air filters for general ventilation- determination of the filtration performance [ S ]. Brussels: Management Centre, rue de Stassart, 1993.
  • 5International Organization for Standardization. ISO 12103-1 As fine i.est dust for filter evaluation, part A, Arizona test dust[S]. Geneva.. ISO, 1999.
  • 6ASHRAE. ANSI/ASHRAE Standard 52.2-2007 Method of testing general ventilation air-cleaning devices for removal efficiency by particle size IS]. Atlanta~ ASHRAE Ine, 2007.
  • 7中国建筑科学研究院.GB/T14295--2008空气过滤器[S].北京:中国标准出版社,2008.
  • 8中国制冷空调工业协会(CRAA).CRAA/DS:2007空气过滤器-分级与标识[s].北京:中国制冷空调工业协会,2007.
  • 9国家技术监督局.GB12218-89一般通风用空气过滤器性能试验方法[S].北京,1989.
  • 10涂光备.对空气过滤器分类及对分类标准的一点浅识[J].洁净技术,1983,1(1):14-18.

二级参考文献34

  • 1涂光备,涂有.对当前医院手术室建设中一些问题的思考[J].暖通空调,2007,37(1):43-47. 被引量:7
  • 2Brandt C,Hott U,Sohr D,et al.Operating room ventilation with laminar airflow shows no protection effect on the surgical site infection rate in orthopedic and abdominal surgery[J].Annals of Surgery,2008,248(5).
  • 3Mangram A J,Horan T C,Pearson M L,et al.Guideline for prevention of surgical site infection[J].Infection Control and Hospital Epidemiology,1999,20(4).
  • 4Owen M L,Reginald A E,Edward J,et al.Ultraclean air and antibiotics for prevention of postoperative infection:a multicenter study of 8 052 joint replacement operations[J].Acta Orthopaedica,1987,58(1).
  • 5Engesaeter L B,Lie S A,Espehaug B,et al.Antibiotic prophylaxis in total hip arthroplasty:effects of antibiotic prophylaxis systemically and in bone cement on the revision rate of 22 170 primary hip replacements followed 0-14 years in the Norwegian Arthroplasty Register[J].Acta Orthopaedica Scand,2003,74(6).
  • 6Torbjm Ahl,Nils Dalen,Hans Jrbeck,et al.Air contamination during hip and knee arthroplasties:horizontal laminar flow randomized vs.conventional ventilation[J].Acta Orthopaedica,1995,66(1):17-20.
  • 7Melling A C,Ali B,Scott E M,et al.Effects of preoperative warming on the incidence of wound infection after clean surgery:a randomized controlled trial[J].Lancet,2001,358(9285):876-880.
  • 8van Griethuysen A J A,Spies-van Rooijen N H,Hoogenboom-Verdegaal A M M.Surveillance of wound infections and a new theatre:unexpected lack of improvement[J].Journal of Hospital Infection,1996,34(2).
  • 9Clarke M T,Lee P T,Roberts C P,et al.Contamination of primary total hip replacements in standard and ultra-clean operating theaters detected by the polymerase chain reaction[J].Acta Orthopaedica,2004,75(5).
  • 10ASHRAE.ANSI/ASHRAE/ASHE Standard 170-2008 Ventilation of health care facilities[S].Atlanta:ASHRAE,2008.

共引文献11

同被引文献72

  • 1涂有,周志坤,涂光备.Evaluating the Effectiveness of Air Pollution Abatement Policy of Hong Kong[J].Transactions of Tianjin University,2007,13(1):70-78. 被引量:2
  • 2黄应来,董大伟,闫兵.双级并联共振腔消声器在大型空压机上的应用[J].噪声与振动控制,2007,27(1):84-86. 被引量:2
  • 3涂光备.制药工业的洁净与空调[M].2版.北京:中国建筑工业出版社,2006:169.
  • 4王书平,时景璞.疾病负担评价常用指标及其应用[J].辽宁医学杂志,2007,21(5):321-324. 被引量:8
  • 5SPILAK M P,KAROTTKI G D,KOLARIKET B,et al.Evaluation of building characteristics in 27dwellings in Denmark and the effect of using particle filtration units on PM2.5concentration[J].Building and Environment,2014,73:55-63.
  • 6SULTAN Z M,NILSSON G J,MAGEE R J.Removal of ultrafine particles indoor air performance of various portable air cleaning devices technologies[J].Building and Environment,2015,84:44-49.
  • 7GAMBLE J F.PM2.5and mortality in long-term prospective cohort studies:cause-effect or statistical associations[J].Environmental Health Prospective,1998,106(9):535-549.
  • 8LOGUE J M,SHERMAN M H,LUNDEN M M,et al.Development and assessment of a physics-based simulation model to investigate residential PM2.5infiltration across the US housing stock[J].Building and Environment,2015,94:21-32.
  • 9EPA.PM standards[EB/OL].[2016-03-02].http:∥www.epa.gov/air/particlepollution∥standards.html.
  • 10朱春,李文迪,缪盈盈,等.某新建住宅PM2.5净化实测分析[C]∥第10届国际绿色建筑节能大会论文集.北京,2014:1-3.

引证文献12

二级引证文献30

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;