期刊文献+

异戊橡胶门尼粘度标准物质定值不确定度的评定

Evaluation of Constant Value Uncertainty for Mooney Viscosity of Isoprene Rubber Certified Reference Material
下载PDF
导出
摘要 对国产异戊橡胶IR 60、IR 80门尼粘度标准物质定值的样品,根据JJF 1059.1-2012分析其测量不确定度的来源并进行评定。分析异戊橡胶IR 60、IR 80不确定度的分量组成分别为样品的均匀性和稳定性、样品测量的重复性、门尼粘度计仪器的工作温度和转子的转速。IR 60、IR 80门尼粘度标准物质的定值的不确定度分别为1.1和1.4。 According to JJF 1059. 1-2012,determined that the instrument temperature and speed,the repeat-ability of measurement results,uniformity and stability of sample were sources of constant value uncertainty of do-mestic IR 60、IR 80 Mooney viscosity certified reference material,and evaluated them. Finally,the results showed that the constant value uncertainty of IR 60、IR 80 were 1. 1 and 1. 4.
出处 《合成材料老化与应用》 2015年第4期72-76,共5页 Synthetic Materials Aging and Application
关键词 不确定度 评定 标准物质 门尼粘度 uncertainty, evaluation, certified reference material, Mooney viscosity
  • 相关文献

参考文献4

  • 1蔡尚脉,陈鹰.GB/T15340-2008天然、合成生胶取样及制样[S].北京:中国标准出版社,2008.
  • 2张菊秀,李海鹰,沈辉,等.GB/T1232.1-2000未硫化橡胶用圆盘剪切粘度计进行测定第1部分:门尼粘度的测定[s].北京:中国标准出版社,2000.
  • 3叶德培,赵峰,施昌彦,等.JJF1059.1-2012测量不确定度评定与表示[s].北京:中国标准出版社,2012.
  • 4全国标准物质管理委员会.分析测试质量保证[M].辽宁:辽宁大学出版社,2004:565;529.