期刊文献+

The Approach of Compensation of Air Refractive Index in Thermal Expansion Coefficients Measurement Based on Laser Feedback Interferometry 被引量:2

The Approach of Compensation of Air Refractive Index in Thermal Expansion Coefficients Measurement Based on Laser Feedback Interferometry
下载PDF
导出
摘要 We present the thermal expansion coefficient (TEC) measurement technology of compensating for the effect of variations in the refractive index based on a Nd: YA G laser feedback system, the beam frequency is shifted by a pair of aeousto-optic modulators and then the heterodyne phase measurement technique is used. The sample measured is placed in a muffle furnace with two coaxial holes opened on the opposite furnace walls. The measurement beams hit perpendicularly and coaxially on each surface of the sample. The reference beams hit on the reference mirror and the high-refiectivity mirror, respectively. By the heterodyne configuration and computing, the influences of the vibration, distortion of the sample supporter and the effect of variations in the refractive index are measured and largely minimized. For validation, the TECs of aluminum samples are determined in the temperature range of 29-748K, confirming not only the precision within 5 × 10-7 K-1 and the accuracy within 0.4% from 298K to 448K but also the high sensitivity non-contact measurement of the lower reflectivity surface induced by the sample oxidization from 448 K to 748 K. We present the thermal expansion coefficient (TEC) measurement technology of compensating for the effect of variations in the refractive index based on a Nd: YA G laser feedback system, the beam frequency is shifted by a pair of aeousto-optic modulators and then the heterodyne phase measurement technique is used. The sample measured is placed in a muffle furnace with two coaxial holes opened on the opposite furnace walls. The measurement beams hit perpendicularly and coaxially on each surface of the sample. The reference beams hit on the reference mirror and the high-refiectivity mirror, respectively. By the heterodyne configuration and computing, the influences of the vibration, distortion of the sample supporter and the effect of variations in the refractive index are measured and largely minimized. For validation, the TECs of aluminum samples are determined in the temperature range of 29-748K, confirming not only the precision within 5 × 10-7 K-1 and the accuracy within 0.4% from 298K to 448K but also the high sensitivity non-contact measurement of the lower reflectivity surface induced by the sample oxidization from 448 K to 748 K.
出处 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第7期17-20,共4页 中国物理快报(英文版)
基金 Supported by the National Natural Science Foundation of China under Grant No F050306
  • 相关文献

参考文献16

  • 1Sch6del R 2008 Meas. Sci. Technol. 19 084003.
  • 2SchSdel R, Walkov A, Zenker M, Bartl G, Meet3 R, Hage-dorn D, Gaiser C, Thummes G and Heltzel S 2012 Meas. Sci. Technol. 23 1425.
  • 3Watanabe H, Yamada N and Okaji M 2004 Int. J. Ther- mophys. 25 221.
  • 4Martelli V, Bianchini G, Natale E, Scarpellini D and Ven- tura G 2013 Meas. Sci. Technol. 24 105203.
  • 5Yamada N, Abe R and Okaji M 2001 Meas. Sci. Technol. 12 2121.
  • 6Liu Y C, Sommer F and Mittemeijer E J 2004 Thermochim. Aeta 413 215.
  • 7Pan B, Xie H M, Hua T and Anand A 2009 Polym. Test. 28 75.
  • 8Liu Z W and Gao J X 2011 Opt. Express 19 17469.
  • 9Kim K, Kim J, Lee J and Jarng S 1997 J. Mater. Sci. Lett. 16 1753.
  • 10Lacot E, Day R and Stoeckel F 2001 Phys. Rev. A 64 043815.

同被引文献24

引证文献2

二级引证文献33

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部