Standardization of proton-induced x-ray emission technique for analysis of thick samples

Standardization of proton-induced x-ray emission technique for analysis of thick samples
下载PDF
导出
摘要 This paper describes the standardization of the proton-induced x-ray emission(PIXE) technique for finding the elemental composition of thick samples. For the standardization, three different samples of standard reference materials(SRMs) were analyzed using this technique and the data were compared with the already known data of these certified SRMs. These samples were selected in order to cover the maximum range of elements in the periodic table. Each sample was irradiated for three different values of collected beam charges at three different times. A proton beam of 2.57 Me V obtained using 5UDH-II Pelletron accelerator was used for excitation of x-rays from the sample. The acquired experimental data were analyzed using the GUPIXWIN software. The results show that the SRM data and the data obtained using the PIXE technique are in good agreement. This paper describes the standardization of the proton-induced x-ray emission(PIXE) technique for finding the elemental composition of thick samples. For the standardization, three different samples of standard reference materials(SRMs) were analyzed using this technique and the data were compared with the already known data of these certified SRMs. These samples were selected in order to cover the maximum range of elements in the periodic table. Each sample was irradiated for three different values of collected beam charges at three different times. A proton beam of 2.57 Me V obtained using 5UDH-II Pelletron accelerator was used for excitation of x-rays from the sample. The acquired experimental data were analyzed using the GUPIXWIN software. The results show that the SRM data and the data obtained using the PIXE technique are in good agreement.
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第9期171-176,共6页 中国物理B(英文版)
关键词 STANDARDIZATION thick samples PIXE analysis standardization,thick samples,PIXE analysis
  • 相关文献

参考文献11

  • 1Johansson S A E and Johansson T B 1976 Nuclear Intrument and Methods 137 473.
  • 2Johansson S A E, Campbell J L and Malmqvist K G 1995 Particle-Induced X-ray Emission Spectroscopy (New York: John Willey & Sons) pp. 147-412.
  • 3Ene A, Popescu I V, Stihi C, Gheboianu A, Pantelica A and Petre C 2009 Rom. Jour. Phy 55 806.
  • 4Cohen D D, Siegele R, Orlic I and Stelcer E 2001 Long Term Accuracy and Precision of PIXE and PIGI Measurments for Thin and Thick Sample Analysis, June 8-12, 2001, Menai, Australia, p. 1.
  • 5Kasahara M, Ogiwara G, Yamamoto K, Park J H and Takahashi 1994 Int. Journal of PIXE 4 155.
  • 6Nejedly Z and Campbell J L 2000 Nuclear Instruments and Methods in Physics Research B 160 415.
  • 7Kabir M H 2007 Particle Induced X-ray Emission (PIXE) Setup and Quantitative Elemental Analysis (Ph. D. Dissertation) (Kochi: University of Technology Japan).
  • 8Govil M 2001 Current Science 80 1542.
  • 9Johansson S A E and Compbell J L 1988 PIXE: A Noval Technique for Elemental Analysis (Chechister: John Wiley & Sons) p. 28.
  • 10Czamamske G K, Sisson T W, Campbell J L and Teesdale W J 1993 American Mineralogist 78 893.