摘要
针对某钢铁公司单双高速线材双环网耦合出现的网络"风暴"问题,从网络系统的配置及网络结构入手,对存在问题进行了进行系统地分析研究,在不影响生产的情况下,选用最佳的改造方案对网络改造,通过实施后网络运行安全可靠,实现了预期目的,可为其它生产线双环网耦合网络系统的应用提供一定的经验。
Systematic analysis and research on the network windstorm happening on the bicyclo-coupling of single and twin wire-rod line production line of a steel company is carried out based on the system configuration and network structure.The network is revamped by the optimum solution without affecting production.The network in reliable operation after the revamped network is implemented,reaching the desired objective.It can provide some experiences for the bicyclo-coupling network on the other production line.
出处
《工业控制计算机》
2015年第8期41-42,共2页
Industrial Control Computer
关键词
网络风暴
网络结构
故障诊断
改造
network windstorm
network structure
failure diagnose
revamping