摘要
机车上的交流牵引电动机在运行40万公里以后,定子线圈引出线出现了不同程度的烧损,文章从操作、弯曲加工、原材料和固定方法等方面对定子线圈引出线烧损的原因进行排查和分析,找出了故障原因并加以解决。
After running 400,000 km,burning out of the stator-coil leads in the AC traction motor of locomotives occurred in varying degrees.Cause of this kind of burning-out were inspected and analyzed in the aspects from operation,bending process,materials and securing method,and then,the cause was found and solving way was suggested.
出处
《电机技术》
2015年第4期37-38,41,共3页
Electrical Machinery Technology
关键词
牵引电机
线圈引出线烧损
可靠性
traction motor
burning out of the statorcoil leads
reliability