VARCO TDS-11SA顶驱辅助电源是为辅助电机提供561.8V/58.66Hz的交流电。运用对辅助电机工作原理分析的方法,利用设备现场运行和验证的手段,达到了对电源更换分析可行性论证的目的,得到了该项方案在实际设备运行现场可以达到很好的应急效果,减少现场生产损失,提高生产经济效益。
The auxiliary power VARCO TDS-11SA Top Drive supplies AC source of 561.8V/58.66Hz for auxiliary motor.The operating principles of the motor are analyzed in this paper to verify the renewal feasibility of the auxiliary power supply by means of field equipment running and testing.The practices of the scheme has proved to be successful in improve economic benefits while reducing losses of production.
出处
《石化技术》
CAS
2015年第8期118-119,201,共3页
Petrochemical Industry Technology
关键词
顶驱辅助电机
辅助变频器
top drive
auxiliary motor
auxiliary transducer