摘要 The performance of an erbium-doped fiber ring laser based intra-cavity absorption gassensor was evaluated with performance enhanced techniques. A multi-line wavelength sweep techniqueand a weighted averaging technique were proposed for better gas detection. By selecting appropriatesystem parameters, 6 strong absorption lines near 1 530 nm of C2H2 were obtained with good spectrumresolution in one scanning period. One group with higher absorption coefficients was used for relativelylow gas concentration detection and the other with lower absorption coefficients was used for relativelyhigh gas concentration. Both the groups can be used for medium gas concentration detection. For variousconcentration cases, by choosing proper absorption lines and performing weighted averaging, detectionaccuracy can be obtained over an extended detection range. The minimum detection limit could be verylow after optimization.
出处 《太赫兹科学与电子信息学报》 2015年第4期653-658,共6页 Journal of Terahertz Science and Electronic Information Technology
  • 相关文献

参考文献16

  • 1Dakin J P,Wade C A,Pinchbeck D,et al. A novel optical fiber methane sensor[C]// Proc. SPIE. London:[s.n.], 1997:187-190.
  • 2Uehara K,Tai H. Remote detection of methane using a 1.66 μm diode l aser i n combination w i t h opt ical fiber[C]// Proc.OFS7., 1990:51-54.
  • 3JIN W,Stewart G,Culshaw B. Source-noise limitation of fiber optic methane sensors[J]. Appl. Optics, 1995,34(13):2345-2349.
  • 4HO H L,WEI J,Demokan M S,et al . Multi poi nt gas detecti on usi ng T DM and w avelength modulation spectroscopy[J].Electronics Letters, 2000,36(14):1191-1193.
  • 5Sigrist M W. Trace gas monitoring by laser photoacoustic spectroscopy and related techniques[J]. Rev. Sci. Instrum, 2003(74):486-490.
  • 6LI J S,GAO X M,LI F,et al. Resonant photoacoustic detection of trace gas with DFB diode l aser[J]. Opt. Laser Technol.,2007(39):1144-1149.
  • 7Baev V M,Eschner J,Paeth E,et al. Intra-cavity spectroscopy with diode lasers[J]. Appl. Phys. B. 1992(55):463-477.
  • 8ZHANG M,ZH A N G Y , WAN G D Ν , e t a l. Fiber ring l a s e r i n t r a -c a v i t y a bsorption spectroscopy for gas sensing[J]. Int. J.Nonlinear. Sci., 2002(3):569-572.
  • 9Wheeler M D,Newman S M,Orr-Ewing A J,et al. Cavity ring-down spectroscopy[J]. J. Chem. Soc. Faraday. Trans,. 1998(94):337-351.
  • 10Stewart G,Shields P,Culshaw B. Development of fibre laser systems for ring-dow n a n d intracavity gas spectroscopy in thenear-IR[J]. Meas. Sci. Technol., 2004(15):1621-1628.