期刊文献+

基于控制信号重置的双变形镜人眼视网膜成像

High-Resolution Retinal Imaging Based on Reset of Control Signals Algorithm
原文传递
导出
摘要 结合人眼自适应光学系统中无需复原Zernike模式系数的特性,提出基于控制信号重置的双变形镜并行控制的改进算法,改进后的算法可以减少矩阵运算量,并能相应地减少存储空间,使其适宜于人眼自适应光学系统的工作特性。对控制算法进行理论介绍,通过模拟仿真证明其可行性,并将算法应用于双变形镜人眼视网膜高分辨率成像系统,实现了对双变形镜的快速稳定控制,获得了眼底视网膜高分辨率图像。模拟仿真和实验结果表明,该算法能够有效地补偿相伴畸变和抑制两个变形镜之间的耦合。 For ocular adaptive optics systems, there is no necessary to calculate Zernike mode coefficients during iterations. A modified algorithm based on reset of control signals is proposed. The modified algorithm is more suitable for ocular adaptive optics because both calculating time and storage space are saved. After principle description and computer simulation, the algorithm is tested on a retinal imaging system which is based on dual deformable mirrors. The two deformable mirror are controlled fast and stably. High resolution retinal images are acquired. Both simulation and experimental results indicate that this algorithm can effectively compensate for phase distortions and significantly suppress the coupling between two deformable mirrors.
出处 《光学学报》 EI CAS CSCD 北大核心 2015年第A01期40-46,共7页 Acta Optica Sinica
基金 国家自然科学基金(61378064,61205202)、国家重大仪器专项(2012YQ120080)
关键词 自适应光学 双变形镜 并行控制 视网膜成像 adaptive optics dual deformable mirrors parallel control retinal imaging
  • 相关文献

参考文献15

  • 1Liang J, Williams D R, Miller D T. Supernormal vision and high-resolution retinal imaging through adaptive optics[J]. J Opt Soc Am A, 1997, 14(11): 2884-2892.
  • 2Thibos L N, Bradley A, Hong X. A statistical model of the aberration structure of normal, well-corrected eyes[J]. Ophthalmic and Physiological Optics, 2002, 22(5): 427-433.
  • 3Chen D C, Jones S M, Silva D A, et al.. High-resolution adaptive optics scanning laser ophthalmoscope with dual deformable mirrors[J]. J Opt Soc Am A, 2007, 24(5): 1305-1312.
  • 4Zou W, Qi X, Burns S A. Woofer-tweeter adaptive optics scanning laser ophthalmoscopic imaging based on Lagrange-multiplier damped least-squares algorithm[J]. Biomedical Optics Express, 2011, 2(7): 1986-2004.
  • 5Zawadzki R J, Cense B, Zhang Y, et al.. Ultrahigh-resolution optical coherence tomography with monochromatic and chromatic aberration correction[J]. Opt Express, 2008, 16(11): 8126-8143.
  • 6Zawadzki R J, Choi S S, Jones S M, et al.. Adaptive optics-optical coherence tomography: optimizing visualization of microscopic retinal structures in three dimensions[J]. J Opt Soc Am A, 2007, 24(5): 1373-1383.
  • 7Cense B, Koperda E, Brown J M, et al.. Volumetric retinal imaging with ultrahigh-resolution spectral-domain optical coherence tomography and adaptive optics using two broadband light sources[J]. Opt Express, 2009, 17(5): 4095-4111.
  • 8Hu S, Xu B, Zhang X, et al.. Double-deformable-mirror adaptive optics system for phase compensation[J]. Appl Opt, 2006, 45(12): 2638-2642.
  • 9叶红卫, 李新阳. 自适应光学系统多变形镜联合闭环控制方法[J]. 中国激光, 2009, 36(s2): 67-72.
  • 10Conan R, Bradley C, Hampton P, et al.. Distributed modal command for a two-deformable-mirror adaptive optics system[J]. Appl Opt, 2007, 46(20): 4329-4340.

二级参考文献14

  • 1凌宁,张雨东,饶学军,李新阳,王成,胡弈云,姜文汉.用于活体人眼视网膜观察的自适应光学成像系统[J].光学学报,2004,24(9):1153-1158. 被引量:45
  • 2凌宁,张雨东,饶学军,王成,胡羿云,姜文汉.High resolution mosaic image of capillaries in human retina by adaptive optics[J].Chinese Optics Letters,2005,3(4):225-226. 被引量:6
  • 3Nathan Doble,Geunyoung Yoon,Li Chenet al.Use of amicroelectromechanical mirror for adaptive optics in the humaneye[].Optics Letters.2002
  • 4Chao Li,Mingliang Xia,Baoguang Jiang et al.Retina imagingsystem with adaptive optics for the eye with or without myopia[].Optics Communication.2009
  • 5Liang J,Williams DR,Miller DT.Supernormal vision and high-resolution retinal imaging through adaptive optics[].Journal of the Optical Society of America A: Optics Image Science and Vision.1997
  • 6LI NG Ning,ZHANG Yu-dong,RAO Xue-jun,et al.Small table-top adaptive optical systems for human retinal i maging[].Proceedings of SPIE the International Society for Optical Engineering.2002
  • 7Chao Li,Mingliang Xia,Dayu Li,Quanquan Mu,Li Xuan.High-resolution retinal imaging through open-loop adaptive optics[].Journal of Biomechanics.2010
  • 8Enrique J Fernndez,Ignacic Tglesias,PabloArtal.Closed loopadaptive optics in the human eye[].Optics Letters.2001
  • 9J.W.Evans,R.J.Zawadzki,S.Jones et al.Performance of aMEMS based AO-OCT system[].Proceedings of SPIE the International Society for Optical Engineering.2008
  • 10蔡冬梅,Seow-Hwang Eng,凌宁,姜文汉.反射型LCOS显示板用于人眼波前像差校正的研究[J].光电子.激光,2008,19(7):992-995. 被引量:3

共引文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部