摘要 通过仿真算例研究了在正常运行工况下导致公共耦合点电压产生不平衡现象的主要因素。以不平衡负序分量为例,提出将公共耦合点上游侧的不平衡源等效为戴维南等值电路,建立了判定公共耦合点不平衡扰动源所处位置的数学分析模型,进而提出了划分不平衡责任的指标。从公共耦合点的电压和电流数据中,选出在负荷侧波动而在系统侧基本保持恒定的数据用于估算上游侧戴维南等值电路参数,该方法不需同步采样数据、不受系统频率变化的影响。仿真算例验证了所提方法的有效性和精确度。 The main factors causing the PCC(Point of Common Coupling) voltage imbalance in normal operating conditions are studied by case simulation. With the negative-sequence component imbalance as an example,the imbalance source at the upstream side of PCC is considered as a Thevenin equivalent circuit to establish a mathematical analysis model for locating the imbalance source at the upstream side of PCC.An index is proposed to assign the imbalance responsibility. The data of PCC voltage and current,which are fluctuated at the load side while kept constant at the system side,are selected to estimate the parameters of the Thevenin equivalent circuit at the upstream side. Immune to the system frequency variation,the proposed method does not need the synchronized sampling data. Simulative study verifies its validity and accuracy.
出处 《电力自动化设备》 EI CSCD 北大核心 2015年第9期43-48,共6页 Electric Power Automation Equipment
基金 国家电网公司科技项目(SGRI-DL-71-14-010) 山东省优秀中青年科学家科研奖励基金资助项目(BS2013NJ005)~~
关键词 配电 电能质量 扰动源 电压不平衡 戴维南等值电路 参数估计 electric power distribution power quality disturbance source voltage imbalance Thevenin equivalent circuit parameter estimation
  • 相关文献

参考文献23

  • 1International Electrotechnical Commission. IEC/TR 61000-3-13 ElectroMagnetic Compatibility(EMC)-limits-assessment of emission limits for the connection of unbalanced installations to MV,HV and EHV[S]. Geneva,Switzerland:IEC,2008.
  • 2袁旭峰,高璐,文劲宇,程时杰.VSC-HVDC三相不平衡控制策略[J].电力自动化设备,2010,30(9):1-5. 被引量:32
  • 3CIGRE Working Group C4.109. Review of disturbance emission assessment techniques[EB/OL]. [2015-05-25 ]. http : //www. research-gate, net/publication/261177644_Review of Disturbance_ Emission_Assessment_Techniques.
  • 4JAYATUNGA U,PERERA S,CIUFO P. Voltage unbalance emission assessment in radial power systems[J]. IEEE Transactions on Power Delivery,2012,27(3) : 1653-1661.
  • 5OLCZYKOWSKI Z,WASOWSKI A. Methods of voltage unbalance estimation in electric power networks[J]. Electrical Power Qua- lity and Utilization,2006,Ⅻ(2):71-76.
  • 6BURCHI G,LAZAROIU C,GOLOVANOV N,et al. Estimation of voltage unbalance in power system supplying high speed railway [J]. Electrical Power Quality and Utilization,2005,Ⅺ(2) :113-119.
  • 7韦刚,张子阳,房正良,张承学.多回输电线路并架的不平衡性分析[J].高电压技术,2004,30(10):9-11. 被引量:58
  • 8ZIA E,DAVID S. Negative phase-sequence voltages on E&W transmission system[J ]. IEEE Transactions on Power Delivery, 2006,21 (3) : 1607-1612.
  • 9NICK C. JOVICA V. Statistical estimation of the source and level of voltage unbalance in distribution networks [J]. IEEE Transactions on Power Delivery,2012,27(3) :1450-1460.
  • 10全国电压电流等级和频率标准化技术委员会.GB/T15543-2008电能质量三相电压不平衡[S].北京:中国标准出版社.2008.