期刊文献+

大化水电厂机组上机架振动分析与轴线调整 被引量:1

Vibration Analysis and Axis Adjustment of Upper Bracket in Dahua Hydropower Station
下载PDF
导出
摘要 大化水电厂5号机组2009年6月投产后机组上机架水平振动严重超标,通过对盘车数据的分析,找出机组上机架振动超标的原因,结合机组检修对转子轴系曲折度不合格及转子圆度超差进行处理,成功解决上机架振动摆度超标问题,达到了预期目标。 Since been put into operation in June 2009, excessive horizontal vibration appeared on the upper bracket of No.5 unit in Dahua hydropower station. The reasons for the excessive vibration were found out through analyzing the axis adjustment data, and the vibration problem was solved through repairing the unqualified rotor shafting tortuosity and the poor rotor roundness during unit maintenance, and the desired result was obtained at last.
出处 《红水河》 2015年第4期26-32,共7页 Hongshui River
关键词 机组上机架 轴线调整 大化水电厂 upper bracket axis adjustment Dahua hydropower station
  • 相关文献

参考文献1

  • 1GB/T8564—2003.水轮发电机组安装技术规范[S].[S].,..

共引文献5

同被引文献13

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;