摘要 目的:比较3种不同运动方式下TF镍钛系统单根锉预备根管的能力。方法:收集临床新鲜拔除的上、下颌磨牙(弯曲度20°~35°)90个(含根管105个),并将其随机分为3组(n=30个牙,35个根管):A组为连续旋转500 r/min、B组为往复旋转300 r/min、C组为连续旋转300 r/min;设定机用马达恒定扭矩3 N·cm,用TF镍钛锉(#25/06)冠向下技术对各组根管进行预备;CBCT拍摄3组根管预备前后的横截面影像,测定根管偏移量和定心比率值,并比较各组根管预备所需时间,显微镜观察各组器械的损耗情况。结果:3组根管预备后,在根管中下段,根管偏移量A组最小、B组最大(P〈0.05);定心比率值C组较好、B组较差(P〈0.05);在根尖和根管中上段两者较一致(P〉0.05);B组预备根管的时间长于A、C组(P〈0.05);B组使用寿命约是A、C组的2倍。结论:TF单根锉(#25/06)配合往复旋转运动模式行根管预备时,用时相对较长,但其安全性也更高;在300、500 r/min连续旋转速度下的操作效果无明显差异。 AIM: To evaluate the endodontic preparation ability of single TF nickel-titanium instrument with different operation mode in the preparation of curved root canal. METHODS: 90 intact molars with 105 root canals were divided into 3 groups( n = 30 molars with 35 canals),the canals of the molars were prepared by the instrument with continuous rotation at 500 r / min( group A),reciprocating movement at 300 r / min( group B) and continuous rotation at 300 r / min( group C) respectively. The CBCT images of the root canal sections were recorded,the root transportation and centering ratio were measured before and after instrumentation. The preparation time,wearing and tearing degree of the instrument were compared. RESULTS: At 3. 0 mm from the anatomic apex,root transportation of group B was significantly greater than that of group A( P〈0. 05),centering ratio of group C was significantly better than that of group B( P〈0. 05). There was no significant difference in root transportation and centering ratio among 3 groups at the distances of 1. 5 mm and 6 mm from the anatomic apex. The preparation time of group B was significantly longer than that of group A and C( P〈0. 05). The lifespan of group B was about 2 times of group A and C. CONCLUSION: TF single nickel- titanium instrument( #25 /06) used with reciprocating mode may produce lower efficiency but higher security. When it is used with continues rotation mode,there is no significant difference between the speeds of 300 r / min and 500 r / min except that the speed of 300 r / min may shorten the lifespan of the instrument.
出处 《牙体牙髓牙周病学杂志》 CAS 2015年第8期477-482,509,共7页 Chinese Journal of Conservative Dentistry
基金 国家自然科学基金(81271134) 上海市科委基础重点项目(08JC1414500) 上海市自然基金(12ZR1417100)
关键词 根管预备 根管偏移 定心比率 TF单根镍钛锉 root canal preparation root transportation centering ratio single TF Nickel-Titanium instrument
  • 相关文献

参考文献32

  • 1范兵,樊明文,边专,吴民凯,P.R.Wesselink.根管偏移对充填材料封闭根管能力的影响[J].口腔医学纵横,2001,17(2):83-87. 被引量:62
  • 2Schafer E, Lohmann D. Efficiency of rotary nickel-titanium FlexMaster instruments compared with stainless steel hand K - Flexofile part I shaping ability in simulated curved canals [ J 1. Int Endod, 2002, 35(6) : 505 -513.
  • 3Vandt J, Bitter K, Neumann K, et al. Ex vivo study on root ca- nal instrumentation of two rotary nickel-titanium systems in com- parison to stainless steel hand instruments [ J ]. Int Endod J, 2009,42( 1 ) :22 -33.
  • 4Shen Y, Qian W, Abtin H, et al. Fatigue testing of controlled memory wire nickel-titanium rotary instruments [ J]. J Ended, 2011,37(7) :997 - 1001.
  • 5Yared G. Canal preparation using only one Ni-Ti rotary instru-ment: preliminary observations I J]. lnt Endod J, 2008, 41 (4) : 339 -344.
  • 6Yared G. Canal preparation with only one reciprocating instru- ment without prior hand filing: a new concept [ J]. Aust Dent Prac, 2011,22: 178.
  • 7Htilsmann M, Peters OA, Dummer PMH. Mechanical prepara- tion of root canals : shaping goals, techniques and means [ J ]. Endod Topics, 2005, 10:30 - 76.
  • 8Gambarini G, Grande NM, Plotino G, et al. Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods [ J ]. J Endod, 2008, 34 ( 8 ) : 1003 - 1005.
  • 9Larsen M, Watanabe I, Gliekman GN, et al. Cyclic fatigue a- nalysis of a new generation of nickel titanium rotary instruments [J]. J Endod, 2009,35(3) :401 -403.
  • 10Gambarini G, Gerosa R, De Luea M, et al. Mechanical proper- ties of a new and improved nickel - titanium alloy for endodontie use: an evaluation of file flexibility [J]. Oral Surg Oral Med O- ral Pathol Oral Radiol Endod, 2008,105 (6) :798 - 800.

二级参考文献69

  • 1[4]Schneider SW.A comparison of canal preparations in straight and curved canals.Oral Surg Oral Med Oral Pathol,1971,32∶271-275
  • 2[5]Lightspeed Technology Inc.Lightspeed reference guide.11707 Raindop Drive,San Antonio,TX,USA:Lightspeed Technology,1994
  • 3[6]Walton R.Cleaning and shaping.In:Walton R,Torabinejad M.Principles and practice of Endodontics.Philadelphia:Sunders,1989,202-204
  • 4[7]Walton R.Obturation.In:Walton R,Torabinejad M.Principles and practice of Endodontics.Philadelphia:Sunders,1989,247-251
  • 5[8]Rybicki R,Zillich R.Apical sealing ability of Thermafil following immediate and delayed post space preparations.J Endod,1994,20∶64-66
  • 6[9]Fan B,Wu MK,Wesselink PR.Coronal leakage along apical root fillings after immediate and delayed post space preparation.Endod Dent Traumatol,1999,15∶124-126
  • 7[10]Southyard DW,Oswald RJ,Natkin E.Instrumentation of curved molar root canals with the Roane technique.J Endod,1987,13∶479-489
  • 8[11]Ehrlich AD,Boyer TJ,Hicks ML,Pelleu GB.Effects of sonic instrumentation on the apical preparation of curved canals.J Endod,1989,15∶200-203
  • 9[12]Wu M-K,De Gee AJ,Wesselink PR,Moorer WR.Fluid transport and bacteria penetration along root canal fillings.Int Endod J,1993,26∶203-208
  • 10[13]Tronstad L.Clinical Endodontics.New York:Thieme,1991,188-199

共引文献83

同被引文献108

引证文献12

二级引证文献49

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部