摘要
在隔离型低压大电流输出的DC/DC变换器中,同步整流电路中存在着纹波电流大的问题。针对此问题,提出了倍流同步整流电路,与传统的整流电路相比,大大减小了纹波电流。通过实验验证了该方案的有效性和优越性。
In this paper,the merits and limitations of current- doubler rectifier are analyzed and synthesized. The current- doubler rectifier is compared with the other second- side rectifier. The conclusion has been drawn that the current- doubler rectifier is suitable for the low- voltage high- current output DC- DC converter.