期刊文献+

330MW汽轮机组刷式汽封应用改造 被引量:2

Reconstruction and Application of Brush Seal on 330 MW Turbine Unit
下载PDF
导出
摘要 介绍了汽轮机通流间隙刚性密封、柔性密封的结构和特点,认为刷式密封具有安装精度要求低、效率高以及泄漏量小等优点。北方联合电力有限责任公司达拉特发电厂通过在330 MW亚临界机组上进行刷式汽封改造,机组高、中、低压缸效率分别比改造前提高了2.354%、1.797%、1.42%,机组发电煤耗率降低了5 g/k Wh左右,每年可节约燃料费用250余万元,经济效益显著。 Introduce the structure and characteristics of the rigid seal and flexible sealof flow gap on the steam turbine.It was considered that the brush type seal had theadvantages of low installation accuracy,high efficiency and small leakage.Brush sealtransformation was made on the 330 MW subcritical unit of North United Power Co.,Ltd.Dalate Power Plant.After the transformation,efficiency of unit′ s high,medium and lowpressure cylinder respectively improved by 2.354%,1.797%,1.42% than that beforemodification,unit power consumption was reduced about 5 g/k Wh,fuel cost was saved morethan 250 million yuan annually.The economic benefit was remarkable.
出处 《内蒙古电力技术》 2015年第4期72-74,85,共4页 Inner Mongolia Electric Power
关键词 330 MW汽轮机组 汽封间隙 刷式汽封 漏汽量 振动 330 MW steam turbine steam seal clearance brush type seal steamleakage amount vibration
  • 相关文献

参考文献5

  • 1苑志军.某600 MW汽轮机汽封间隙调整对机组效率的影响分析[J].陕西电力,2013,41(7):97-99. 被引量:4
  • 2徐灏.机械设计手册[M].北京:机械工业出版社,2001..
  • 3马修光,韩建春,李燕平.达拉特发电厂#3汽轮机大修后热力试验报告[R].呼和浩特:内蒙古电力科学研究院,2014:6-7.
  • 4都明亮,赵金峰,赵明亮.达拉特发电厂综合升级改造实施后3号机组性能测试暨实施效果报告.长春:吉林省电力科学研究院有限公司,2014:24-26.
  • 5王伟峰.达拉特发电厂7号汽轮机通流改造前性能试验.西安:西安热工研究院有限公司.2014:3-4.

二级参考文献5

共引文献68

同被引文献14

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部