摘要
通过比对建筑空调冷水机组、冷冻水循环泵、冷却水循环泵这三部分的设备能耗,针对性地对其进行了全年能耗的计算,并进行了分析研究,给出了较为详细的计算方法,为实际能效测评工作提供一定的参考。
Through comparing the equipment energy consumption of building air-conditioning water chiller,chilled water circulating pump and cooling water circulating pump,the paper calculates corresponding whole-year energy consumption,and makes analysis research,and finally shows specific computation methods,which has provided certain guidance for actual energy efficiency testing and evaluating.
出处
《山西建筑》
2015年第27期174-176,共3页
Shanxi Architecture
关键词
建筑能效测评标识
空调系统
能耗计算方法
building energy efficiency testing and labeling
air-conditioning system
energy-consumption computation method