期刊文献+

模拟电子交叉配血的临床分析 被引量:3

Clinical Analysis of Simulated Electric Blood Cross Matching Tests
下载PDF
导出
摘要 通过红细胞输注的回顾性分析,探讨电子交叉配血的影响因素。采用全自动血型分析仪IH-1000检测我院受血者与供血者的ABO血型、不规则抗体筛查、交叉配血以及直接抗人球蛋白试验。在对红细胞进行电子交叉配血发现,14 762例受血者中有3例两次血型结果不一致,占0.02%,有101例不规则抗体筛查阳性,占0.68%,有26例交叉配血不合,占0.17%;29 608单位RBC供血者中有26单位RBC直接抗人球蛋白试验阳性,占0.09%,出现交叉配血不合。结论为具备ABO血型鉴定准确性、不规则抗体筛查阴性、直接抗人球蛋白阴性的结果适合电子交叉配血。 To analyse the affecting factors of electric blood cross matching test in clinical application. Using automatic blood analyzer IH-1000 detects the hospital's recipient and donor ABO blood group, irregular antibody screening, crossmatch and direct Coombs test. In erythrocytes electronic crossmatch the authors found 14 762 cases of recipients in three cases two blood inconsistent results, accounting for 0.02%, there were 101 cases of irregular antibody screening positive, accounting for 0.68%, there were 26 cases of cross-matching of blood incompatibility, accounting for 0.17% ; 29 608 units of blood donors, 26 RBC units direct coombs test was positive, accounting for 0.09%, there crossmatch incompatibility. The results identified the accuracy of the ABO blood group, irregular antibody screening was negative, negative direct coombs for electronic crossmatch. Key Words:blood transfusion, electronic crossmatch, ABO blood typing, irregular antibody screening, direct antiglobulin tests
出处 《医学与哲学(B)》 2015年第8期30-31,共2页 Medicine & Philosophy(B)
关键词 输血 电子交叉配血 ABO血型 不规则抗体筛查 直接抗人球蛋白试验 blood transfusion, electronic crossmatch, ABO blood typing, irregular antibody screening, direct antiglobulin tests
  • 相关文献

参考文献6

二级参考文献52

  • 1王依波.佳木斯地区临床用血现状调查分析[J].黑龙江医药科学,2004,27(5):34-34. 被引量:1
  • 2金振良.不同类型医院临床用血管理调查分析[J].中国医院,2005,9(10):39-40. 被引量:8
  • 3Widman FK.输血技术手册[M].北京:人民卫生出版社,1985.336.
  • 4陈会友,付涌水,汪传喜,江朝富,陆志刚,林东军,胡永红,周振海,冯莹,陈盛亭,原耀光,赖福才,王心田,张伟,吴峰.广州地区临床用血现状调查分析[J].中国输血杂志,2007,20(4):331-333. 被引量:40
  • 5Onder Arslan. Electronic crossmatching. Transfusion medicine Re-views,2006,20(l) ;75-79.
  • 6Arslan 0. Donors'blood group declaration before donation can beused as a tool for electronic crossmatching. Transfus Med,2005,15(6):487-492.
  • 7Cox C,Enno A,Deveridge S,et al. Remote electronic blood releasesystem. Transfusion, 1997,37(9) :960-964.
  • 8Mercy K, Ellen F. Pretransfusion testing without serologiccrossmatch : appproaches to ensure patient safety. Vox Sang, 2000,78(2):113-118.
  • 9Goddard K,Shabestari 0,Kay JD,et al. Formatively evaluating theimportance of different aspects of an electronic blood transfusionsystem from the end users,point of view : a questionnaire study. StudHealth Technol Inform,2010,160( Pt 2) : 1211-1215.
  • 10Arslan 0. Electronic crossmatching. Transfus Med Rev, 2006,20(1):75-79.