直流锅炉水冷壁管连续爆管分析

Analysis on Leakage of Once-through Boiler Water Tube
下载PDF
导出
摘要 对超临界机组直流锅炉水冷壁管连续爆管泄漏进行宏观分析、金相组织分析、机械性能检测和X射线衍射检测,原因为异物堵塞过热爆管泄漏;深入分析了超临界机组直流锅炉水冷壁管异物产生的原因,提出传统的检修工艺对超临界直流锅炉不利影响的预防措施。 Tube leakage of once-through boiler water tube wall in supercritical units is analyzed by means of macrostructure,metallographic,mechanical properties and XRD detection.It is concluded that the tube leakage is caused by overheating which is due to foreign bodies block.On the basis of thorough analysis and research on the causes of foreign body into supercritical once-through boiler,some preventive measures are proposed to reduce the adverse effect of traditional repair technology.
出处 《山东电力技术》 2015年第8期43-46,共4页 Shandong Electric Power
关键词 直流锅炉 水冷壁 连续爆管 once-through boiler water wall tube leakage
  • 相关文献

参考文献3

二级参考文献3

  • 1Acklin L Laubli F.Calculation of the dynamic behaviour of heat exchange with the aid of analogue computers[J].Sulzer Technical Review,No.4,1960.
  • 2Ray R.Bowman H.F.A Nonlinear Dynamic Model of a Once-through Subcritical Steam Generator.Transaction of the ASME,1976.
  • 3范永胜,徐治皋,陈来九.超临界直流锅炉蒸汽发生器的建模与仿真研究(二)[J].中国电机工程学报,1998,18(5):350-356. 被引量:33