橡胶油中PCA和PAHs含量的快速检测方法 被引量:2

Rapid Determination of PCA and PAHs Contents in Rubber Oil
下载PDF
导出
摘要 用薄层色谱/氢火焰离子化检测器(TLC/FID)和气相色谱-质谱联用(GC-MS)分别快速检测橡胶油的多环芳香族化合物(PCA)和多环芳烃(PAHs)含量。结果表明:TLC/FID与IP 346检测的橡胶油PCA含量接近,TLC/FID检测法的加标回收率为95%--105%;GC-MS与德国BIU公司检测的橡胶油PAHs含量接近,GC-MS检测法的加标回收率为97%~104%。2种检测方法操作简单、试剂用量小、准确度高、重复性好。 The PCA and PAHs contents in rubber oil were measured rapidly by TLC/FID and GC-MS, respectively. The experimental testing results showed that the PCAs content of rubber oil measured by TLC/FID was close to the IP 346 method, while the recovery of added standard was 95%-105% by using TLC/FID. The PAHs content of rubber oil detected by GC-MS was close to the result measured by German company BIU, and the recovery of added standard was 97%-104% with GC-MS method. These two detection methods are simple, consume only small amount of testing reagents, and provide high accuracy and good reproducibility.
出处 《橡胶科技》 2015年第9期49-53,共5页 Rubber Science and Technology