能谱CT成像中扫描参数的优化 被引量:2

Optimization of scanning parameters in spectral CT imaging
下载PDF
导出
摘要 目的:探讨能谱CT不同扫描参数对测量结果的影响,优化最佳扫描参数。方法:采用GE公司标准水膜,5个扫描参数有序组合,测量552组数据,水膜上选取10个测量点测量CT值,利用概率统计分析法,优化扫描参数。结果:能谱CT水膜成像的扫描参数对测量结果有显著影响,不同参数影响效果不同,不同测量位置对测量结果也有影响。结论:通过能谱CT扫描参数的理论模型和实验数据结合分析,可以优化扫描参数,对临床诊断结果提供可靠的分析依据。 Objective To investigate the effect of different scanning parameters in spectral CT on measurement results, and optimize the best scanning parameters. Methods The GE standard water model was applied to orderly combine 5 scanning parameters, and measure 552 groups of data. Ten measurement points on water model were selected to measure CT values, and the probability and statistics analysis was applied to optimize the scanning parameters. Results The scanning parameters of spectrum CT water model imaging had remarkable effects on measurement results. Different parameters had different effects on results. And the different measurement points also affected measurement results. Conclusion By analyzing the theoretical model and experimental data of spectral CT scanning parameters, the scanning parameters can be optimized to provide the reliable analytic basis for the clinical diagnosis results.
出处 《中国医学物理学杂志》 CSCD 2015年第5期664-668,共5页 Chinese Journal of Medical Physics
基金 国家自然科学基金(81470078)
关键词 能谱成像 水膜 参数优化 多元回归分析 spectral imaging water model parameters optimization multiple regression analysis
  • 相关文献

参考文献13

  • 1Carolin S. Calculating a water poverty index[J]. World Dev, 2012, 30(7): 1195-1210.
  • 2汪嘉杨,王文圣,李祚泳,张碧.基于TS-SVM模型的水安全评价[J].水资源保护,2010,26(2):1-4. 被引量:21
  • 3李祚泳,张正健,邹艳玲.蛙跳算法优化的地下水质评价的参数化组合算子模型[J].环境工程,2010,28(5):94-97. 被引量:5
  • 4Matsumoto K, Jinzaki M, Tanami Y, et al. Virtual monochromatic spectral imaging with fast kilo voltages witching: Improved image quality as compared with that obtained with conventional 120-kVp CT[J]. Radiology, 2011,259(1): 257-262.
  • 5Yu L, Leng S, McCollough CH. Dual-energy CT-based monochro- matic imaging[J]. AJR Am J Roentgenol, 2012, 199: S9-S15.
  • 6Ho LM, Yoshizumi TT, Hurwitz LM, et al. Dual energy versus- single energy MDCT: measurement of radiation dose using adultabdominal imaging protocols[J]. Acad Radiol, 2009, 16(11): 1400-1407.
  • 7吉强,洪洋.医学影像物理学[M].北京:人民卫生出版社,2009:5-25.
  • 8Landry G, Joao S, Mathieu G, et al. Deriving effective atomic numbers from DECT basedon a parameterization of the ratio of high and low linear attenuation coefficients[J]. Phys Med Biol, 2013, 58: 6851-6866.
  • 9Toepker M, Moritz T, Krauss B, et al. Virtual non-contrast in second- generation, dual-energy computed tomography: reliability of atten- uation values[J], Eur J Radiol, 2012, 81: e398-e405.
  • 10Primak AN, Ramirez JC, Liu X, et al. Improved dual-energy mat- erial discrimination for dual-source CT by means of additional spectral filtration[J]. IVied Phys, 2009, 36: 1359-1369.

二级参考文献35

共引文献38

同被引文献32

引证文献2

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部