摘要 目的研究消毒后消化内镜中分离出的铜绿假单胞菌对常用消毒剂的抗性。方法采用肉汤稀释法,测定了3种消毒剂对从消毒后消化内镜中分离的铜绿假单胞菌的最小抑菌浓度和最小杀菌浓度。结果经测定,常用戊二醛和万金医用器械消毒液对铜绿假单胞菌分离株和标准株之间的MIC、MBC值相差2倍。结论消毒后消化内镜中分离的铜绿假单胞菌对常用戊二醛和万金医用器械消毒液产生了一定的抗药性。
出处 《中国消毒学杂志》 CAS 北大核心 2015年第9期948-950,共3页 Chinese Journal of Disinfection
  • 相关文献

参考文献2

二级参考文献28

  • 1杨滨,李泓.496株铜绿色假单胞菌的药敏分析[J].海峡药学,1996,8(2):84-84. 被引量:2
  • 2Russell AD,Hammond SA.Bacterial resistance to antiseptics and disinfectants[J].J Hosp Infect,1986; 7:213.
  • 3Nagai I,Ogase H.Absence of role for plasmids in resistance to muliple disinfectants in three strains of bacteria[ J ].J Hosp Infect,1990; 15:149.
  • 4Sandossi M,Rossm HW,and Wireman JW.Observations of resistance and cross-resistance to fomaldehyde and a fomaldehyde condensate biocide in Pseudomonas aeruginosa[J].Int Biodeterior,1985; 21(1):105.
  • 5Sandossi M,Rossm oore HW,Wireman JW.Induction and selection of fomaldyde-based resistance in Pseudomonas aeruginosa[J].J Industrial Microbiol,1986; 1(1):97.
  • 6Hingst V,Klippel KM,Sommtang HG.Epidemiology of microbial resistance to bioxides[ J].Zentralbl Hyg Umweltmed,1995; 197(1 -3):232.
  • 7Nakahara H,Asakawa M,Yonekura I,et al.Benzethonium chloride resistance in Pseudomonas aeruginosa isolated from clinical lesions[J].Zentralbl Bacteriol Microbiol Hyg,1984; 257(3):409.
  • 8Stickler DJ.Susceptibility of antibiotic-resistant gram-negative bacteria to biocides:a perspective from the study of catheter biofilms[ J].Journal of Applied Microbiology,2002; 92 (Suppl):163S.
  • 9Koljalg S,Naaber P,Mikelsaar M.Antibiotic resistance as an indicator of bacterial chlorhexidine susceptibility[ J].J Hosp Infect,2002; 51(2):106.
  • 10Gilbert P,Brown MRW.Influence of growth rate and nutrient limitation on the gross cellular composition of Pseudomonas aeruginosa and its resistance to 3-and 4-chlorophenol[ J].J Bacteriol,1978; 133:1066.