期刊文献+

Investigation of noise properties in grating-based x-ray phase tomography with reverse projection method

Investigation of noise properties in grating-based x-ray phase tomography with reverse projection method
下载PDF
导出
摘要 The relationship between noise variance and spatial resolution in grating-based x-ray phase computed tomography(PCT) imaging is investigated with reverse projection extraction method, and the noise variances of the reconstructed absorption coefficient and refractive index decrement are compared. For the differential phase contrast method, the noise variance in the differential projection images follows the same inverse-square law with spatial resolution as in conventional absorption-based x-ray imaging projections. However, both theoretical analysis and simulations demonstrate that in PCT the noise variance of the reconstructed refractive index decrement scales with spatial resolution follows an inverse linear relationship at fixed slice thickness, while the noise variance of the reconstructed absorption coefficient conforms with the inverse cubic law. The results indicate that, for the same noise variance level, PCT imaging may enable higher spatial resolution than conventional absorption computed tomography(ACT), while ACT benefits more from degraded spatial resolution. This could be a useful guidance in imaging the inner structure of the sample in higher spatial resolution. The relationship between noise variance and spatial resolution in grating-based x-ray phase computed tomography(PCT) imaging is investigated with reverse projection extraction method, and the noise variances of the reconstructed absorption coefficient and refractive index decrement are compared. For the differential phase contrast method, the noise variance in the differential projection images follows the same inverse-square law with spatial resolution as in conventional absorption-based x-ray imaging projections. However, both theoretical analysis and simulations demonstrate that in PCT the noise variance of the reconstructed refractive index decrement scales with spatial resolution follows an inverse linear relationship at fixed slice thickness, while the noise variance of the reconstructed absorption coefficient conforms with the inverse cubic law. The results indicate that, for the same noise variance level, PCT imaging may enable higher spatial resolution than conventional absorption computed tomography(ACT), while ACT benefits more from degraded spatial resolution. This could be a useful guidance in imaging the inner structure of the sample in higher spatial resolution.
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第10期622-628,共7页 中国物理B(英文版)
基金 Project supported by the National Basic Research Program of China(Grant No.2012CB825800) the Science Fund for Creative Research Groups,the Knowledge Innovation Program of the Chinese Academy of Sciences(Grant Nos.KJCX2-YW-N42 and Y4545320Y2) the National Natural Science Foundation of China(Grant Nos.11475170,11205157,11305173,11205189,11375225,11321503,11179004,and U1332109)
关键词 x-ray imaging noise variance spatial resolution computed tomography (CT) x-ray imaging, noise variance, spatial resolution, computed tomography (CT)
  • 相关文献

参考文献40

  • 1Momose A, Yashiro W, Kido K, Kiyohara J, Makifuchi C, Ito T, Nagatsuka S, Honda C, Noda D, Hattori T, Endo T, Nagashima M and Tanaka J 2014 Phil. Trans. R. Soc. A 372 20130023.
  • 2Weitkamp T, Diaz A, David C, Pfeiffer F, Stampanoni M, Cloetens P and Ziegler E 2005 Opt. Express 13 6296.
  • 3Zhu P P, Zhang K, Wang Z L, Liu Y J, Liu X S, Wu Z Y, Mcdonald S A, Marone F and Stampanoni M 2010 Proc. Natl. Acad. Sci. USA 107 13576.
  • 4Momose A, Yashiro W, Kuwabara H and Kawabata K 2009 Jpn. J. Appl. Phys. 48 076512.
  • 5Pfeiffer F, Bech M, Bunk O, Kraft P, Eikenberry E F, Bronnimann C, Grunzweig C and David C 2008 Nat. Mater. 7 134.
  • 6Huang Z F, Chen Z Q, Zhang L, Kang K J, Ding F, Wang Z T and Ma H Z 2010 Opt. Express 18 10222.
  • 7Wang D J, Wang Z L, Gao K, Ge X, Wu Z, Zhu P P and Wu Z Y 2014 Radiat. Phys. Chem. 95 86.
  • 8Pfeiffer F, Bech M, Bunk O, Donath T, Henrich B, Kraft P and David C 2009 J. Appl. Phys. 105 102006.
  • 9Munro P R T, Ignatyev K, Speller R D and Olivo A 2011 Nucl. Instrum. Methods Phys. Res. Sect. A-Accel. Spectrom. Dect. Assoc. Equip. 652 824.
  • 10Olivo A, Gkoumas S, Endrizzi M, Hagen C K, Szafraniec M B, Diemoz P C, Munro P R T, Ignatyev K, Johnson B, Horrocks J A, Vinnicombe S J, Jones J L and Speller R D 2013 Med. Phys. 40 090701.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部