期刊文献+

An Improved Turn-On Aptasensor for Thrombin Detection Using Split Aptamer Fragments and Graphene Oxide 被引量:1

An Improved Turn-On Aptasensor for Thrombin Detection Using Split Aptamer Fragments and Graphene Oxide
原文传递
导出
摘要 An improved tum-on aptasensor for thrombin detection using split aptamer fragments and graphene oxide (GO) was reported. The thrombin-binding aptamer (Aptl5) was split into two parts for target recognition, an 8-base se- quence labeled with fluorescein (FAM-Apt-A) and a 7-base oligonucleotide sequence (Apt-B). In the absence of target protein, the fluorescence of FAM-Apt-A/Apt-B was quenched by GO through n-n stacking between GO and single-stranded DNA. However, when thrombin was introduced into the system, a target-induced G-quadruplex forms with two split aptamer fragments and thrombin. The fluorescence recovered due to weak interaction between G-quadruplex and GO. Compared to the strategy using intact aptamer, probe concentration was lowered, and an improved sensitivity was obtained. Moreover, heating process to avoid unfavorable secondary structure was avoided due to the use of shorter split aptamer fragments. An improved tum-on aptasensor for thrombin detection using split aptamer fragments and graphene oxide (GO) was reported. The thrombin-binding aptamer (Aptl5) was split into two parts for target recognition, an 8-base se- quence labeled with fluorescein (FAM-Apt-A) and a 7-base oligonucleotide sequence (Apt-B). In the absence of target protein, the fluorescence of FAM-Apt-A/Apt-B was quenched by GO through n-n stacking between GO and single-stranded DNA. However, when thrombin was introduced into the system, a target-induced G-quadruplex forms with two split aptamer fragments and thrombin. The fluorescence recovered due to weak interaction between G-quadruplex and GO. Compared to the strategy using intact aptamer, probe concentration was lowered, and an improved sensitivity was obtained. Moreover, heating process to avoid unfavorable secondary structure was avoided due to the use of shorter split aptamer fragments.
出处 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2015年第8期981-986,共6页 中国化学(英文版)
关键词 sensor split aptamer graphene oxide sensor, split aptamer, graphene oxide
  • 相关文献

参考文献54

  • 1Ellington, A. D.; Szostak, J. W. Nature 1990, 346, 818.
  • 2Bao Lain, N.; Jeong, J. E.; Jung, 1. H.; Kim, B.; Van Sang, L.; Kim, I.; Kyhm, K.; Woo, H. Y. Adv. Funct. Mater. 2014, 24, 1748.
  • 3Song, W.; Zhang, Q.; Xie, X.; Zhang, S. Biosens. Bioelectron. 2014, 61, 51.
  • 4Pavlov, V.; Xiao, Y.; Shlyahovsky, B.; Willner, 1. J. Am. Chem. Soc. 2004, 126, 11768.
  • 5Liang, H. R.; Hu, G. Q.; Xue, X. H.; Li, L.; Zheng, X. X.; Gao, Y. W. Yang, S. T.; Xia, X. Z. Virus Res. 2014, 184, 7.
  • 6Kim, Y. S.; Chung, J.; Song, M. Y.; Jurng, J.; Kim, B. C. Biosens. Bioelectron. 2014, 54, 195.
  • 7Qu, L.; Xu, J.; Tan, X.; Liu, Z.; Xu, L.; Peng, R. ACS Appl. Mater. lnter. 2014, 6, 7309.
  • 8Kubik, M. F.; Stephens, A. W.; Schneider, D.; Marlar, R. A.; Tasset, D. Nucleic Acids Res. 1994, 22, 2619.
  • 9Pestourie, C.; Tavitian, B.; Duconge, F. Biochimie 2005, 87, 921.
  • 10Song, S.; Wang, L.; Li, J.; Zhao, J.; Fan, C. Anal. Chem. 2008, 27,108.

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部