期刊文献+

Effects of Driving Mode on the Performance of Multiple-Chamber Piezoelectric Pumps with Multiple Actuators 被引量:4

Effects of Driving Mode on the Performance of Multiple-Chamber Piezoelectric Pumps with Multiple Actuators
下载PDF
导出
摘要 Due to the limited output capability of piezoelectric diaphragm pumps, the driving voltage is frequently increased to obtain the desired output. However, the excessive voltage application may lead to a large deformation in the piezoelectric ceramics, which could cause it to breakdown or become damaged. Therefore, increasing the number of chambers to obtain the desired output is proposed. Using a check-valve quintuple-chamber pump with quintuple piezoelectric actuators, the characteristics of the pump under different driving modes are investigated through experiments. By changing the number and connection mode of working actuators, pump performances in terms of flow rate and backpressure are tested at a voltage of 150 V with a frequency range of 60 Hz -400 Hz. Experiment results indicate that the properties of the multiple-chamber pump change significantly with distinct working chambers even though the number of pumping chambers is the same. Pump performance declines as the distance between the working actuators increases. Moreover, pump performance declines dramatically when the working piezoelectric actuator closest to the outlet is involved. The maximum backpressures of the pump with triple, quadruple, and quintuple actuators are increased by 39%, 83%, and 128%, respectively, compared with the pump with double working actuators; the corresponding maximum flow rates of the pumps are simply increased by 25.9%, 49.2%, and 67.8%, respectively. The proposed research offers practical guidance for the effective utilization of the multiple-chamber pumps under different driving modes. Due to the limited output capability of piezoelectric diaphragm pumps, the driving voltage is frequently increased to obtain the desired output. However, the excessive voltage application may lead to a large deformation in the piezoelectric ceramics, which could cause it to breakdown or become damaged. Therefore, increasing the number of chambers to obtain the desired output is proposed. Using a check-valve quintuple-chamber pump with quintuple piezoelectric actuators, the characteristics of the pump under different driving modes are investigated through experiments. By changing the number and connection mode of working actuators, pump performances in terms of flow rate and backpressure are tested at a voltage of 150 V with a frequency range of 60 Hz -400 Hz. Experiment results indicate that the properties of the multiple-chamber pump change significantly with distinct working chambers even though the number of pumping chambers is the same. Pump performance declines as the distance between the working actuators increases. Moreover, pump performance declines dramatically when the working piezoelectric actuator closest to the outlet is involved. The maximum backpressures of the pump with triple, quadruple, and quintuple actuators are increased by 39%, 83%, and 128%, respectively, compared with the pump with double working actuators; the corresponding maximum flow rates of the pumps are simply increased by 25.9%, 49.2%, and 67.8%, respectively. The proposed research offers practical guidance for the effective utilization of the multiple-chamber pumps under different driving modes.
出处 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2015年第5期954-963,共10页 中国机械工程学报(英文版)
基金 Supported by National Natural Science Foundation of China(Grant Nos.51205366,51205367,51377147) Zhejiang Provincial Natural Science Foundation of China(Grant No.LQ13E050007)
关键词 piezoelectric pump multiple chambers multiple actuators driving mode flow rate backpressure piezoelectric pump, multiple chambers, multiple actuators, driving mode, flow rate, backpressure
  • 相关文献

参考文献31

  • 1MAHNAMA A, NOURBAKHSH A, GHORBANIASL G. A survey on the applications of implantable micropump systems in drug delivery[J]. Current Drug Delivery, 2014, 11(1): 123-131.
  • 2SALARI A, NAVI M, DALTON C. A novel alternating current multiple array electrothermal micropump for lab-on-a-chip applications[J], Biomicrofluidics, 2015, 9(1): 014113.1-14.
  • 3KIM H, ASTLE A A, NAJAFI K, et al. An integrated electrostatic peristaltic 18-stage gas micropump with active microvalves[J]. Journal of Microelectromechanical Systems, 2015, 24(1): 192-206.
  • 4IVERSON B D, GARIMELLA S V. Recent advances in microscale pumping technologies: a review and evaluation[J]. Microfluidics andNanofluidics, 2008, 5(2): 145-174.
  • 5SPENCER W J, CORBETT W T, DOMINGUEZ L R, et al. An electronically controlled piezoelectric insulin pump and valves[J]. IEEE Transactions on Sonics and Ultrasonics, 1978, 25(3): 153-156.
  • 6VALDOVINOS J, WILLIAMS R J, LEVI D S, et al. Evaluating piezoelectric hydraulic pumps as drivers for pulsatile pediatric ventricular assist devices[J]. Journal of Intelligent Material Systems and Structures, 2014, 25(10): 1276-1285.
  • 7LENG Xuefei,ZHANG Jianhui,JIANG Yan,WANG Shouyin,ZHAO Chunsheng.Simulation Analysis and Experimental Verification of Spiral-tube-type Valveless Piezoelectric Pump with Gyroscopic Effect[J].Chinese Journal of Mechanical Engineering,2014,27(4):822-829. 被引量:5
  • 8TANAKA Y. A peristaltic pump integrated on a 100% glass microchip using computer controlled piezoelectric actuators[J]. Micromachines, 2014, 5(2): 289-299.
  • 9HU Xiaoqi,ZHANG Jianhui,HUANG Yi,XIA Qixiao,HUANG Weiqing,ZHAO Chunsheng.Principle and Experimental Verification of Caudal-fin-type Piezoelectric-stack Pump with Variable-cross-section Oscillating Vibrator[J].Chinese Journal of Mechanical Engineering,2012,25(1):128-136. 被引量:12
  • 10ZHANG Z H, KAN J W, CHENG G M, et al. A piezoelectric micropump with an integrated sensor based on space-division multiplexing[J]. Sensors and Actuators A." Physical, 2013, 203: 29-36.

二级参考文献12

  • 1HUANG Yi1, ZHANG JianHui1, HU XiaoQi1, XIA QiXiao2, HUANG WeiQing1 & ZHAO ChunSheng1 1 Department of Aerospace Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China,2 Department of Mechanical and Electrical Engineering, Beijing Union University, Beijing 100020, China.Dynamics analysis and experiment on the fishtailing type of valveless piezoelectric pump with rectangular vibrator[J].Science China(Technological Sciences),2010,53(12):3241-3247. 被引量:10
  • 2TODA M.Theory of air flow generation by a resonant type PVF2 bimorph cantilever vibrator. Ferroelectrics . 1979
  • 3BASAK S,RAMAN A,GARIMELLA S V.Dynamic response optimization of asymmetrically configured piezoelectric fans. ASME 19th Biennial Conference on Mechanical Vibration and Noise . 2005
  • 4YOO J H,HONG J I,CAO W.Piezoelectric ce-ramic bimorph coupled to thin metal plate as cool-ing fan for electronic devices. Sensors and Ac-tuators A:Physical . 2000
  • 5Piresa R E F,Vatanabeb S L,De Oliveirab A R,etal.Water cooling system using a piezoelectrically ac-tuated flow pump for a medical headlight system. Proceedings of SPIE the International Society for Optical Engineering . 2007
  • 6CCERO R D L,SANDRO L V,ANDRES C,etal.A biomimetic piezoelectric pump:Computa-tional and experimental characterization. Sen-sors and Actuators A:Physical . 2009
  • 7Michael Sfakiotakis,Lane D M,Bruce J,et al.Review of Fish Swimming Modes for Aquatic Locomotion. IEEE Journal of Oceanic Engineering . 1999
  • 8Lindsey,C.C.Form, function and locomotory habits in fish. Fish Physiology . 1978
  • 9XIA Qixiao,ZHANG Jianhui,LEI Hong,CHENG Wei.Theoretical Analysis and Experimental Verification on Flow Field of Piezoelectric Pump with Unsymmetrical Slopes Element[J].Chinese Journal of Mechanical Engineering,2009,22(5):735-744. 被引量:18
  • 10ZHANG JianHui,XIA QiXiao,HUANG Yi,LENG XueFei,HUANG Jun,ZHAO ChunSheng.Theory and experimental verification of valveless piezoelectric pump with rotatable unsymmetrical slopes[J].Science China(Technological Sciences),2011,54(11):3070-3077. 被引量:8

共引文献15

同被引文献28

引证文献4

二级引证文献38

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部