期刊文献+

倾角与充液率对板翅式热管散热器传热的影响 被引量:1

The influence of inclination and filling ratio on the heat transfer performance of plate- fin heat pipe radiator
下载PDF
导出
摘要 试验难以实现倾斜角、充液率对动车牵引变流器散热用板翅式热管散热器传热性能影响的研究,因此以实际的板翅式热管散热器为例,通过建立数学模型,采用ICEPAK数值模拟软件,分析了倾斜角、充液率对散热器有效传热面积比、总传热系数、传热量、空腔底板温度场分布的影响,得到该散热器的最佳充液率范围为0.5~0.6。 Doing experiments is extremely difficult to study the influence of the inclination angle and filling ratio on the heat transfer performance of the plate -fin heat pipe radiator used in CRH locomotive traction converter . Therefore, establishing mathematical model and using numerical simulation software ICEPAK , it takes the real plate-fin heat pipe radiator as example and analyzes the influence of inclination and filling ratio on the effective heat transfer area percent , overall coefficient of heat transfer , heat dissipation and temperature distribution of cavity substrate plate .It obtains the optimum filling ratio range ranging from 0.5~0.6.
出处 《机械设计与制造工程》 2015年第8期74-78,共5页 Machine Design and Manufacturing Engineering
关键词 板翅式热管散热器 充液率 倾斜角 有效传热面积比 温度分布 plate-fin heat pipe radiator filling ratio angle of inclination effective heat transfer area percent temperature distribution
  • 相关文献

参考文献8

二级参考文献25

  • 1S.D.Garner,李春阳.热管——一种高效实用的散热方法[J].变流技术与电力牵引,2004(6):41-43. 被引量:2
  • 2李春阳,徐景秋.热管散热器在新型变流装置中的应用[J].机车电传动,2005(2):14-18. 被引量:8
  • 3宗朝晖.现代电力电子的冷却技术[J].变流技术与电力牵引,2007(4):6-12. 被引量:19
  • 4Chang Je-Young, Prasher Ravi S. Evaporative Thermal Performance of Vapor Chambers Under Nonuniform Heating Conditions [J]. Journal of Heat Transfer, 2008, 130(12): 121501.
  • 5Tan B K, Huang X Y. A Study of IVlultiple Heat Sources on a Flat Plate Heat Pipe Using a Point Source Approach [J]. Int J Heat and Mass Transfer, 2000, 43:3755-3764.
  • 6"WANG Shuangfeng, CHEN Jinjian, HU Yanxin, et al. Effect of Evaporation Section and Condensation Section Length on Thermal Performance of Flat Plate Heat Pipe [J]. Applied Thermal Engineering, 2011, 31:2367 2373.
  • 7Wang Y, Vafai K. An Experimental Investigation of the Thermal Performance of an Asymmetrical Flat Plate Heat Pipe [J]. International Journal of Heat and Mass Transfer, 2000, 43:2657 2668.
  • 8Koito Yasushi, Hodizuki M, Saito M. Numerical Analysis and Experimental Verification on Thermal Fluid Phenomena in a Vapor Chamber [J]. Applied Thermal Engineering, 2006, 26: 1669- 1676.
  • 9王正星.功率器件用风冷散热器的新型结构[J].机车电传动,1986(1):40-43.
  • 10Thomas Luttin. IGBT technology in high-power applications [ J]. International Railway Journal, 2000(4):28-29.