摘要 并联式三坐标测量机具有测量范围大和精度高的特点。针对这些特点,介绍了一种四面体坐标测量机,可对机床或空间某一点位置进行测量。由于机构的几何误差以及各级伸缩杆之间的不可避免的间隙所带来的误差使得测量机存在一定的测量误差。文中针对伸缩杆杆长误差建立了测量机的测量误差模型,并通过MATLAB软件对测量机测量空间进行误差仿真分析,得到了测量机在机床工作空间的误差缩放规律。通过计算分析得出杆长误差及被测点初始位置误差对测量机测量误差的影响仅在0.2%~1.5%之间,满足测量要求。 Parallel three dimensional( 3D) coordinate measuring machine( CMM) has characteristics of a large measurement range and high accuracy. A tetrahedron CMM was described which can measure the position of a point in space or machine tool by aimed at these characteristics. There were some measurement errors existed in the CMM due to the geometric errors and the error of inevitable gaps of Telescopic rod at all levels. A measurement error model of the CMM was established by aimed at the error of Telescopic rod length,and through MATLAB software,the measurement errors of CMM space were analyzed with simulation so as to obtain error telescopic law of workspace of machine tool in the CMM. By analysis with calculation,it is obtained that the error of Telescopic rod length and measured initial position errors which impacted on the measuring machine error are only between 0. 2% ~ 1. 5%,and meet the measurement requirements.
出处 《机床与液压》 北大核心 2015年第17期72-75,92,共5页 Machine Tool & Hydraulics
基金 江苏省科技支撑计划-工业部分的资助项目(BE2011193)
关键词 并联机构测量机 三坐标测量机 测量模型 误差分析 Parallel Mechanism Measuring Machine CMM Measuring Model Error Analysis
  • 相关文献

参考文献2

二级参考文献16

  • 1林璨.三坐标测量机的精度检定与位置误差补偿[J].现代计量测试,1995,3(2):21-24. 被引量:2
  • 2宋开臣.三坐标测量机激光扫描测量系统的研究:博士学位论文[M].天津:天津大学,1997..
  • 3宋开臣,博士学位论文,1997年
  • 4张国雄,机床,1986年,8期,37页
  • 5Zhang Guoxiong,Ann CIRP,1985年,34卷,445页
  • 6付中正,叶东,张之江,车仁生.新型关节式三坐标测量机的研究[J]工具技术,1997(01).
  • 7Dr Yin-Lin Shen,Xianping Zhang. Modelling of pretravel for touch trigger probes on indexable probe heads on coordinate measuring machines[J] 1997,The International Journal of Advanced Manufacturing Technology(3):206~213
  • 8Dr Jenq Shyong Chen,Cheng Chang Ling. Improving the machine accuracy through machine tool metrology and error correction[J] 1996,The International Journal of Advanced Manufacturing Technology(3):198~205
  • 9Dr X. Q. Tang,B. J. Davies. Integration of inspection planning system and CMM via DMIS[J] 1995,The International Journal of Advanced Manufacturing Technology(6):422~426
  • 10宋开臣,张奕群,李书和,张国雄.三坐标测量机动态误差补偿的研究[J].仪器仪表学报,1999,20(1):23-25. 被引量:11

共引文献27

同被引文献8

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部