对高架仓库的发展情况和火灾特点进行阐述,通过分析对比高架仓库火灾自动报警系统设计实际案例中线型光束感烟火灾探测器与吸气式感烟火灾探测器设计方案,对高架仓库的火灾自动报警系统设计进行探讨。
The development and fire features of high-rack warehouse are introduced; the design for automatic fire alarm system of high-rack warehouse is discussed by analysis and comparison of the design schemes of liner beam type smoke fire detector and aspirated smoke fire detector in actual design cases of automatic fire alarm system of high-rack warehouse.
出处
《建筑电气》
2015年第9期22-24,共3页
Building Electricity
关键词
高架仓库
火灾自动报警系统
剩余电流式电气火灾监控系统
吸气式感烟火灾探测器
线型光束感烟火灾探测器
故障电弧
探测器报警值
泄漏电流
high-rack warehouse
automatic fire alarm system
residual current type alarm and monitering system for electric fire protection
aspirated smoke fire detector
liner beam type smoke fire detector
fault arc
alarm value of fire detector
leakage current