为更好地模拟近海温排水三维结构特征,基于FVCOM模型建立了阳西海域某电厂高精度三维温排水数值模型,模型较好地反映了温升的垂向分层特点。基于三维温排水数学模型的取排水方案比选结果表明,无论是分列式、还是差位式布置方案,模型都可以计算出较好的比选结果。该文基于FVCOM模型建立的三维温排水数值模型可为电厂取排水布置方案比选工作提供支持,为冷却水工程方案优化布置服务。
In order to study the 3D structure characteristics of the cooling water discharged into coastal based on FVCOM tidal flow module, a high resolution numerical model of 3D cooling water has been developed by the finite volume method .The thermal stratification buoyancy effect of the cooling water can be simulated by the model , and better result for both the type of intake -outlet layout of “Outlet-in /outside-Intake” or the“outlet-side-Intake”can be given .It is useful for the 3-D Cooling Water model that can give advices on the layout for Selection on Scheme of the cooling water project .