摘要 本文基于WIA-PA无线网络技术实现了石化水电计量系统的优化管理,提高了生产效率,但同时也带来了网络安全风险。针对石化水电计量的无线网络技术及安全问题,从实际应用的角度,设计了基于WIA-PA的水电数据采集计量的技术架构,对石化系统存在的安全风险和防护需求进行分析,利用OPC工业防火墙的访问控制技术,有效实现了石化水电计量系统的安全防护。 This paper achieves the optimization management of the petrochemical hydropower measurement system and improves the production efifciency based on WIA-PA wireless network technology, but also brings the network security risks. In order to resolve the wireless network technology and security problem from practical application, the WIA-PA technology framework of data acquisition and measurement is designed, it analyzes the security risks and protection requirements of petrochemical system. By using the OPC industrial ifrewall, the security protection of the petrochemical hydropower measurement system is achieved.
出处 《仪器仪表标准化与计量》 2015年第4期14-17,共4页 Instrument Standardization & Metrology
基金 中国科学院网络化控制系统重点实验室开放课题"工业控制网络异常行为建模 在线入侵检测及自学习方法研究"
关键词 石化 WIA-PA无线网络 水电计量 工业防火墙 Petrochemical WIA-PA Hydropower Measurement Industrial ifrewall
  • 相关文献

参考文献12

二级参考文献159

  • 1.OPC技术综述[Z].www.opcchina.org/download.,.
  • 2GeierJ 王群 李馥娟 叶清杨.无线局域网 [M].北京:人民邮电出版社,2001..
  • 3MullerNJ.Bluetooth Demystified [M].北京:人民邮电出版社,2001..
  • 4www.industrialwireless.cn.
  • 5ISA SPI00. Technical requirements for securable wireless industrial field networks[ R] ,2006.
  • 6Blaine T. Challenges to wireless adoption at scale [ R]. Meeting of WirelessHART Working Group,2006.
  • 7HART Communication Foundation. HART 7.0 Specification [ S ] , 2008.
  • 8IEC 62601 Ed. 1.0 [ S ]. WIA-PA communication network and communication profile ,2009.
  • 9霍尼韦尔.无线解决方案技术规范[R/OL].[2009-08-16].http: //www, honeywell, com.
  • 10www.hart.com.

共引文献238

同被引文献7

引证文献1

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部