低管电压CT联合迭代重建技术在眼眶CT检查中的应用 被引量:5

Combined application of low tube voltage and iterative reconstruction for CT imaging of the orbit
下载PDF
导出
摘要 目的:探讨低管电压联合迭代重建技术(IR)在眼眶CT检查中的应用价值。方法 :2014年6月—2015年1月于我院行眼眶CT平扫患者90例,随机分为120 k V组(A组)、100 k V组(B组)、80 k V组(C组),每组30例。A组行滤波反投影(FBP)重建,B组和C组行IR重建(idose3)。对各组进行图像质量主观及客观评价,记录各组辐射剂量。对图像质量及辐射剂量进行统计学分析。结果:A、B、C组各组的有效剂量分别为(7.3±0.7)m Sv、(4.5±0.3)m Sv、(2.2±0.2)m Sv,各组间差异有统计学意义。各组图像均满足诊断要求,图像质量评分均高于3分,且两观察者对图像质量评价的一致性好或非常好。低剂量组的图像背景噪声较常规剂量组高,且差异有统计学意义(P<0.05)。结论:低管电压联合IR技术在眼眶CT检查中能明显降低CT辐射剂量同时图像满足诊断要求。 Objective: To investigate the combined application value of low tube voltage and iterative reconstruction(IR) for CT imaging of the orbit. Methods: From June 2014 to January 2015 in our hospital, 90 patients were referred for orbit CT. Patients were randomly assigned into three groups: 120 kV group(group A), 100 kV group(group B) and 80 kV group(group C), with 30 cases in each group. Group A underwent filtered back projection(FBP) reconstruction while group B and C underwent IR reconstruction. Subjective and objective evaluations were performed on image quality and radiation dose was recorded for each group, which were statistically analyzed. Results: The average effective dose of group A, B and C were (7.3±0.7) mSv, (4.5±0.3) mSv and (2.2±0.2) mSv respectively. There were significant difference among groups. The images of the three groups all met the diagnostic requirement. All image quality scores were higher than 3 points. The consistency of the two observers in evaluating image quality was either good or very good. The image background noise of low-dose group was higher than that of standard dose group, and the difference was statistically significant (P〈0.05). Conclusion: Low tube voltage combined with IR algorithm in orbit CT examination can significantly reduce radiation dose, and the image quality can meet the diag- nostic requirement.
出处 《中国临床医学影像杂志》 CAS 北大核心 2015年第9期623-626,630,共5页 Journal of China Clinic Medical Imaging
关键词 眼眶 体层摄影术 螺旋计算机 Orbit Tomography, spiral computed
  • 相关文献

参考文献16

  • 1NakauraT, Awai K, Oda S, et al. Low -kilovoltage, high-tube-current MDCT of liver in thin adults: pilot study evaluating radi-ation dose, image quality and display settings[J]. AJR, 2011, 196(6): 1332-1338.
  • 2SilvaAC, Lawder HJ, Hara A, et al. Innovations in CT dose re-duction strategy: application of the adaptive statistical iterativereconstruction Algorithm[J]. AJR, 2010, 194(1): 191-199.
  • 3HaraAK, Paden RG, Silva AC, et al. Iterative reconstructiontechnique for reducing body radiation dose at CT: feasibilitystudy[J]. AJR, 2009,193(3): 764-771.
  • 4KlinkT, Obmann V, Heverhagen J, et al. Reducing CT radiationdose with iterative reconstruction algorithms: the influence of scanand reconstruction parameters on image quality and CTDIvol [J].Eur J Radiol, 2014,83(9): 1645-1654.
  • 5白万晶,宁刚.儿童低剂量CT检查技术的研究进展[J].中华妇幼临床医学杂志(电子版),2009,5(3):78-82. 被引量:16
  • 6KambadakoneAR, Prakash P, Hahn PF, et al. Low-dose CT ex-aminations in Crohn’s disease: Impact on image quality, diagnos-tic performance, and radiation dose[J]. AJR, 2010,195(1): 78-88.
  • 7刘万里,薛茜,曹明芹,马金凤.用SPSS实现完全随机设计多组比较秩和检验的多重比较[J].地方病通报,2007,22(2):27-29. 被引量:95
  • 80’ConnellJE,Hartnett C, Hickey-Dwyer M, et al. Reconstruc-tion of orbital floor blow-out fractures with autogenous iliac crestbone: A retrospective study including maxillofacial and ophthal-mology perspectives[J]. J Craniomaxillofac Surg, 2015,43(2): 192-198.
  • 9Tsao K,Cheng A, Goss A, et al. The use of cone beam comput-ed tomography in the postoperative assessment of orbital wallfracture reconstruction [J]. J Craniofac Surg, 2014, 25 (4): 1150-1154.
  • 10Nguyen PK, Wu JC. Radiation exposure from imaging tests: isthere an increased cancer risk.[J]. Expert Rev Cardiovasc Ther,2011,9(2): 177-183.

二级参考文献18

共引文献109

同被引文献35

引证文献5

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部