摘要 针对某电厂一次风机液压装置故障,引起锅炉燃烧困难导致机组跳闸事故。通过对一次风机液压装置解体检查分析,主要原因为液压装置故障引起挡板操作失灵。结合实际提出避免一次风机跳闸损坏的技术措施,保障了机组安全运行。 Facing hydraulic device fault of primary air fan in given power plant which cause difficuhs of boiler combustion and unit trip fault, strip inspection are carried out on the hydraulic device of primary air fan. The reasons are that hydraulic device fault caused by back plate malfunctioning. In this paper, technological measures are proposed to avoid trip fault of primary air fan and to ensure the safe operation of the power system.
作者 王慎刚
出处 《东北电力技术》 2015年第7期33-36,共4页 Northeast Electric Power Technology
关键词 一次风机 液压 汽包 油泵 Primary air fan Hydraulic Boiler The oil pump
  • 相关文献

参考文献5

二级参考文献32

  • 1袁泉,吴志鹏,井春茹.影响火力发电厂风机可靠性的因素及措施[J].东北电力技术,2005,26(10):48-50. 被引量:6
  • 2臧亚利.降低300MW机组一次风机喘振次数的措施[J].江西电力,2005,29(6):35-37. 被引量:1
  • 3陈虹微,王荣杰.风机振动分析与处理[J].噪声与振动控制,2007,27(2):49-52. 被引量:26
  • 4郭立君.泵与风机[M].北京:中国电力出版社,2004.
  • 5DL/T468-2004,电站锅炉风机选型和使用导则[S].
  • 6GB13223-2011.火电厂大气污染物排放标准[S].环境保护部:国家质量监督检验检疫总局,2011.
  • 7全国风机标准化技术委员会.JB/T8689-1998中华人民共和国机械行业标准通风机振动检测及其限值[S].北京:中国标准出版社,1998:265.
  • 8内蒙古电力(集团)有限责任公司.转动机械检修技术[M].呼和浩特:内蒙古电力(集团)有限责任公司,1994:41-259.
  • 9电力行业锅炉标准化技术委员会.DL/T748.5—2001火力发电厂锅炉机组检修导则第5部分:烟风系统检修[S].北京:中国电力出版社,2001:315.
  • 10上海鼓风机厂有限公司.FAF型电站动叶可调轴流一次风机安装使用维护说明书[R].上海:上海鼓风机厂有限公司,2005:17-31.