期刊文献+

东曲煤矿STS-360变电站综合自动化系统的应用研究 被引量:1

Study on Application of Dongqu Mine STS-360 Substation Integrative Automation System
下载PDF
导出
摘要 为加强变电站运行的安全性、可靠性,东曲煤矿在羊圈港35 k V变电站运行了STS-360变电站综合自动化监控系统,对该系统的监控后台界面进行了详细设计,充分利用CSA881通信管理机智能装置,实现通信规约转换、数据采集、控制等综合自动化功能。实践表明,该系统在羊圈港35 k V变电站的运行,大大提高了其操作性和可维护性,为类似生产条件提供了参考。 In order to improve the safety and reliability of transformer substation, STS-360 substation integrated automation monitoring and control system was operated in Yangquangang 35 kV transformer substation, monitor interface of the system was designed in detail, CSA881 communication management wit device was fully used to realize communication protocols conversion, data acquisition, control, and integrated automation functions. The result showed that the system improved interoperability and maintainability and provided reference for similar production.
作者 姜效星
出处 《煤炭与化工》 CAS 2015年第9期56-59,共4页 Coal and Chemical Industry
关键词 35 KV变电站 综合自动化系统 CSA881通信管理机 35 kV substation Integrated automation system CSA881 communication management machine