介绍了变压器励磁涌流的形成机理、特点及对于变压器差动保护的影响,分析了基于相控分合闸技术的励磁涌流控制技术的原理和过程,并通过动模试验系统进行实验。实验结果表明,该方法能够较为准确地实现对励磁涌流的控制,提高对变压器差动保护检测的准确度和效率。
Introduction was made to the formation mechanism, characteristics and the inlfuence of transformer inrush current on trans-former’s differential protection. Analysis was made to the principle and process of inrush current control technique based on phase controlled breaking-closing technique. Experiments were conducted in the dynamic simulation system. The results show that this method could accu-rately realize the inrush current control relatively, improving the accuracy and efifciency of test on transformer’s differential protection.
出处
《电工电气》
2015年第9期32-36,共5页
Electrotechnics Electric
关键词
励磁涌流
相控分合闸技术
差动保护
涌流控制
inrush current
phase controlled breaking-closing technique
differential protection
inrush current control