摘要 该文介绍一种基于磁吻合技术与机械传动相结合的消化道吻合器的设计及其工作原理。该吻合器由枪头与枪身组成。枪头是可以更换的,分为近端和远端两部分。枪头近端可以固定到枪身上,远端用于做荷包包埋。实现吻合的操作流程与钉式吻合器类似,最终通过枪头内的一对磁环实现消化道磁吻合。该装置的优点在于将磁吻合技术与机械传动技术联合,实现磁吻合操作的简化,使磁吻合安全、可靠、无缝线、无异物残留等优点得以突出,有利于磁吻合技术的临床应用推广。同时枪身可以反复使用,枪头可以更换;有利于降低医疗成本、节省医疗资源;而磁环排出体外,体内无金属物残留,也能使患者受益最大化。 A new anastomat for digestive tract operations, based on the magnetic compressive technique and mechanical transmission mechanism, is composed of a removable head and a reusable body. The head includes two parts: the proximal end can be fixed to the body, and the distal end could be used for performing a purse string suture. The procedure of anastomosis is similar to that of the stapler, and the anastomoses is established using a pair of magnetic rings. The instrument makes magnamosis more simple and feasible, and it would facilitate the clinical applicaion. The body of the anastomat is reusable and the head could be replaced according to the clinical scenarios, these could reduce the medical cost. The magnetic rings would be excreted with the feces, and there is no foreign body response at last.
出处 《中国医疗器械杂志》 CAS 2015年第5期331-333,共3页 Chinese Journal of Medical Instrumentation
基金 陕西省战略性新兴产业重大产品(群)(2011KTCQ03-12)
关键词 磁吻合技术 机械传动装置 吻合器 magnetic compressive technique mechanical transmission mechanism anastomat
  • 相关文献

参考文献2

二级参考文献38

  • 1Oestreich AE.Worldwide survey of damage from swallowing multiple magnets.Pediatr Radiol 2009; 39:142-7.
  • 2Pryor HI,Lange PA,Bader A,et al.Multiple magnetic foreign body ingestion:a surgical problem.J Am Coll Surg 2007; 205:182-6.
  • 3Galizia G,Lieto E,Castellano P,et al.Comparison between the biofragmentable anastomosis ring and stapled anastomoses in the extraperitoneal rectum:a prospective,randomized study.Int J Colorectal Dis 1999; 14:286-90.
  • 4White RN.Modified functional end-to-end stapled intestinal anastomosis:technique and clinical results in 15 dogs.J Small Anim Pract 2008; 49:274-81.
  • 5Wang Y,Cai X,Cal H,et al.Experimental study of colonic anastomosis with a degradable stent in a porcine model.Am J Surg 2010; 199:833-9.
  • 6Ballantyne GH.The experimental basis of intestinal su-turing-effect of surgical technique,inflammation,and infection on enteric wound-healing.Dis Colon Rectum 1984; 27:61-71.
  • 7Owens MW,Grisham MB.Cytokines increase proliferation of human intestinal smooth-muscle cells-possible role in inflammation-induced stricture formation.Inflammation 1993; 17:481-7.
  • 8Kaidar-Person O,Rosenthal RI,Wexner SD,et al.Compression anastomosis:history and clinical considerations.Am 3 Surg 2008; 195:818-26.
  • 9Buchberg BS,Masoomi H,Bergman H,et al.The use of a compression device as an alternative to hand-sewn and stapled colorectal anastomoses:is three a crowd? J Gastrointest Surg 2011; 15:304-10.
  • 10Lim CBB,Goldin RD,Darzi A,et al.Characterization of materials eliciting foreign body reaction in stapled human gastrointestinal anastomoses.Br J Surg 2008; 95:1044-50.

共引文献55

同被引文献81

引证文献7

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部