摘要
从地铁客流情况入手。根据GB16899-2011对载荷的定义,分析了自动扶梯额定载荷的合理取值.自动扶梯的实际工作时间以及载荷特性。将实际测试与理论分析相结合。提出了电动机功率计算的经验公式。
From the passenger flow of subway, according to the definition of load in GB16899- 2011, the reasonable value of rated load, actual working hours and load characteristics of escalator are analyzed. Combined practical test with theoretical analysis, experience calculation formula for motor power is proposed.
出处
《中国电梯》
2015年第17期32-34,共3页
China Elevator