期刊文献+

Factors Affecting Corneal Hysteresis in Taiwan Residents Adults 被引量:3

Factors Affecting Corneal Hysteresis in Taiwan Residents Adults
下载PDF
导出
摘要 Purpose: To investigate the correlation of various corneal hysteresis(CH) factors in Chinese adults.Methods: From January 2009 to November 2011, the healthy right eyes of a total of 292 adults were recruited into the study. Goldmann-correlated intraocular pressure(IOPG) and CH were measured using an ocular response analyzer(ORA).Central corneal thickness was measured using the ORA's integrated handheld ultrasonic pachymeter. The IOLMaster was used to obtain the ocular biometric measurements including axial length, anterior chamber depth, and keratometric values.The Pearson correlation coefficient was used to test correlations between CH and quantitative factors. The chi-square test was used to detect differences in categorical values.Results: Longer axial length(P =0.0001), lower IOPG(P =0.03), older age(P=0.003),and thinner central corneal thickness(P=0.0001) were significantly associated with lower CH.The anterior chamber depth(P=0.34), gender(P =0.23), and corneal curvature(P=0.18) had no relationship to CH.Conclusion: Various factors including axial length, intraocular pressure, age, and central corneal thickness can affect measurement of corneal biomechanical properties in Chinese adults.But the anterior chamber depth, gender, and corneal curvature were irrelevant to CH. Purpose: To investigate the correlation of various corneal hysteresis (CH) factors in Chinese adults. Methods: From January 2009 to November 2011, the healthy right eyes of a total of 292 adults were recruited into the study. Goldmann-correlated intraocular pressure (IOPG) and CH were measured using an ocular response analyzer (ORA).Central corneal thickness was measured using the ORA's integrated handheld ultrasonic pachymeter. The IOLMaster was used to obtain the ocular biometric measurements including axial length, anterior chamber depth, and keratometric values. The Pearson correlation coefficient was used to test correlations between CH and quantitative factors. The chi-square test was used to detect differences in categorical values. Results: Longer axial length (P=0.0001), lower IOPG (P= 0.03), older age (P=0.003), and thinner central corneal thick- ness(P=0.0001) were significantly associated with lower CH. The anterior chamber depth(P=0.34), gender(P=0.23), and corneal curvature (P=0.18) had no relationship to CH. Conclusion: Various factors including axial length, intraocular pressure, age, and cenlral corneal thickness can affect measurement of corneal biomechanical properties in Chinese adults. But the anterior chamber depth, gender, and corneal curvature were irrelevant to CH. (Eye Science 2015; 30: 89-93)
出处 《Eye Science》 2015年第3期89-93,共5页 眼科学报(英文版)
基金 supported by grants of Far Eastern Memorial Hospital (FEMH-99-HHC-002), Taiwan, China
关键词 角膜 影响因素 滞后 成人 台湾地区 生物测量 生物力学特性 超声测厚仪 corneal hysteresis biometry ocular response analyzer axial length central corneal thickness
  • 相关文献

参考文献32

  • 1Luce DA. Determining in vivo biomeehanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg 2005; 31(1) : 156-162.
  • 2Liu J, Roberts CJ. Influence of corneal biomechanical properties on intraocular pressure measurement; quantita- tive analysis.J Cataract Refract Surg 2005;31 (1):146- 155.
  • 3Pepose JS, Feigenbaum SK, Qazi MA,et al. Changes in corneal biomechanics and intraocular pressure following LASIK using static, dynamic, and noncontact tonometry. Am J Ophthalmol 2007; 143 (1) : 39-47.
  • 4Congdon NG, Broman AT, Bandeen-Roche K,et al.Cen- tral corneal thickness and corneal hysteresis associated with glaucoma damage.Am J Ophthalmol 2006;141 (5): 868-875.
  • 5Del Buey MA, Crist6bal JA, Ascaso FJ,et al.Biome- chanical properties of the cornea in Fnchs' corneal dystro- phy. Invest Ophthalmol Vis Sci 2009; 50 (7) : 3199-3202.
  • 6Ortiz D,Pinero D,Shabayek MH,et al.Comeal biome- chanical properties in normal, post-laser in situ ker- atomileusis, and keratoconic eyes.J Cataract Refract Surg 2007; 33(8) : 1371-1375.
  • 7Goldich Y,Barkana Y,Gerber Y,et al.Effect of diabetes mellitus on biomechanical parameters of the cornea. J Cataract Refract Surg 2009; 35 (4) : 715-719.
  • 8Kamiya K, Shimizu K, Ohmoto F.Effect of aging on corneal biomechanical parameters using the ocular re- sponse analyzer. J Refract Surg 2009; 25(10) : 888-893.
  • 9Fontes BM, Ambr6sio R Jr, Alonso RS, et al.Comeal biomechanical metrics in eyes with refraction of -19.00 to +9.00 D in healthy Brazilian patients. J Refract Surg 2008;24(9) :941-945.
  • 10Kamiya K, Hagishima M, Fujimura F, et al. Factors af- fecting corneal hysteresis in normal eyes. Graefes Arch Clin Exp Ophthalmol 2008; 246 (10) : 1491-1494.

同被引文献13

引证文献3

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部