摘要 针对长时间使用电脑造成的视疲劳问题,研制出了爽目电脑护眼仪.该护眼仪采用双向光干预技术,其中,纵向光采用8 000K色温的仿自然光光源,横向光通过特殊设计的护眼色谱卡后变为波段为550~700nm的组合光谱.对比爽目电脑护眼仪使用前后的效果,使用后被试者的主观评价更好、满意程度更高,客观试验结果表明,闪光临界融合频率和眨眼次数在使用该护眼仪后得到了明显增加,经统计学t检验处理,差异具有显著性(P<0.01).由此可知该爽目电脑护眼仪通过调整外部视觉光环境有效缓解了电脑视疲劳. To solve the problem of computer visual fatigue caused by the prolonged use of computers, a computer eye SPA was developed. The computer eye SPA applies the technology of bidirectional optical interference. The vertical light imitates natural light source of 8 000 K temperature, the transverse light absorbs the light of other bands via a eye protection spectrum card developed by a special designed micro- nano-sized material and only reflect a combination spectrum ranged in 550 - 700 nm. The research indicates that the subjective evaluation and the degree of satisfaction are better compared users with non- users. Objective experimental results show that the number of critical flicker fusion and blinking frequency have increased after using the computer eye he concluded that the computer eye SPA can adjust computer visual fatigue. SPA, the different is significant(P^O. 01). It can the external visual optical environment to relieve
出处 《光子学报》 EI CAS CSCD 北大核心 2015年第9期39-43,共5页 Acta Photonica Sinica
基金 国家自然科学基金(Nos.61372050 61250008)资助~~
关键词 应用光学 光学技术与仪器 爽目电脑护眼仪 双向光干预技术 闪光临界融合频率 眨眼次数 电脑视疲劳 Computer eye SPA Bidirectional optical interference technology Critical flicker fusion Blinking frequency Computer visual fatigue
  • 相关文献

参考文献15

二级参考文献48

  • 1俞丽华,沈迎九.CIE眩光指数(CGI)的应用研究[J].照明工程学报,1993,4(1):22-28. 被引量:2
  • 2花醒飞,刘乃涛,梁秉文.大功率LED在书写台灯中的应用[J].中国照明,2005(9):32-35. 被引量:3
  • 3石路.光源色温对人体生物节律和体温调节的影响[J].人类工效学,2006,12(3):53-55. 被引量:24
  • 4徐欢,李湘宁,周果.基于Zemax软件的大齿距等厚菲涅尔透镜的设计[J].上海理工大学学报,2007,29(1):99-102. 被引量:9
  • 5KAWAI T.3D displays and applications[J].Displays,2002,23(1-2):48-56.
  • 6FAO Yu hong, WANG Qiong hua, GU Jun, al. AulostereoscoDic three dimensional projcclor based on two parallax barriers[J]. Optics Letters ,2009,34(20) :3220-3222.
  • 7MPHEPO W, HUANG Y, SHIEH H D. Zero barrier, zero crosstalk aulo sleresoscopic 3D display syslem for cinema 8. home theater muhi user seltings[C]. IEEE, 2009 Society for Information Display,San Antonio.2009:615-618.
  • 8BOEV A, GOTCHEV A, EGIAZARIAN K. Crosstalk measurement methodoh)gy for autn-stereoscopie screens [C]. Proc 3DTVCON,2007,Kos,Greece,2007:1-4.
  • 9LAMBOOIJ M, FORTUIN M, IJSSEI.STEIJN W A.et al.Measuring visual discomfort associated with 3d displays[C]. SPIE, 2009,7237 : 1 - 12.
  • 10KUZE J, UKAI K. Subjective evaluation of visual fatigue caused by motion images[J].Displays,2008,29(2):159 166.

共引文献154

同被引文献12

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部