期刊文献+

Influence of working gas properties on MWPC anode wire modulation effect 被引量:2

Influence of working gas properties on MWPC anode wire modulation effect
原文传递
导出
摘要 For MWPCs used for X-ray position detection, simulation studies of the anode wire modulation effect of the detector were carried out using the Garfield program. Different gas mixtures were used as the working gas in the simulation, so as to obtain the influence of the X-ray cross section and electron diffusion coefficient of the working gases on the anode wire modulation effect of an MWPC with anode wire spacing of 2 mm. Results show that, though a working gas with higher X-ray cross section implies a larger average drift distance for the ionized electrons, such gas mixtures are of little use in improving the anode wire modulation effect of MWPCs. It is found that the transverse electron diffusion coefficient is the determining factor for the extent of the anode wire modulation effect in the detector. For MWPCs used for X-ray position detection, simulation studies of the anode wire modulation effect of the detector were carried out using the Garfield program. Different gas mixtures were used as the working gas in the simulation, so as to obtain the influence of the X-ray cross section and electron diffusion coefficient of the working gases on the anode wire modulation effect of an MWPC with anode wire spacing of 2 mm. Results show that, though a working gas with higher X-ray cross section implies a larger average drift distance for the ionized electrons, such gas mixtures are of little use in improving the anode wire modulation effect of MWPCs. It is found that the transverse electron diffusion coefficient is the determining factor for the extent of the anode wire modulation effect in the detector.
出处 《Chinese Physics C》 SCIE CAS CSCD 2015年第10期82-86,共5页 中国物理C(英文版)
基金 Supported by Scientific Research Fund of Sichuan Provincial Education Department(11ZA140)
关键词 Garfield simulation anode wire modulation working gas MWPC Garfield simulation, anode wire modulation, working gas, MWPC
  • 相关文献

参考文献1

二级参考文献4

  • 1G. C. Smith, B. u. The Linearity Performance of a Two - Dimensional, X - ray Proportional Chamber with 0.58 mm Anode Wire Spacing[J]. IEEE Trans. Nu- cl. Sci. NS,1995,42(4):541-547.
  • 2E. Mathieson,G. C. Smith. Performance studies of a multiwire chamber, with lmm anode wire spacing, to be used for 2 - D position - sensitive detection of x - rays [J]. IEEE Trans. Nucl. Sci. NS,1990, 37(2):187 - 191.
  • 3Rob Veenhof. Garfield - simulation of gaseous de- tectors[ EB/OL]. http ://garfield. web. cem. ch/garf- ield/.
  • 4M.J. Berger, J.H. Hubbell, S. M. Seltzer, et al. XCOM: Photon Cross Sections Database [ EB/OL]. http ://www. nist. gov/pml/data/xcom.

共引文献1

同被引文献5

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部