A novel transient rotor current control scheme of a doubly-fed induction generator equipped with superconducting magnetic energy storage for voltage and frequency support

A novel transient rotor current control scheme of a doubly-fed induction generator equipped with superconducting magnetic energy storage for voltage and frequency support
下载PDF
导出
摘要 A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator(DFIG)equipped with a superconducting magnetic energy storage(SMES) device to enhance its transient voltage and frequency support capacity during grid faults. The SMES connected to the DC-link capacitor of the DFIG is controlled to regulate the transient dc-link voltage so that the whole capacity of the grid side converter(GSC) is dedicated to injecting reactive power to the grid for the transient voltage support. However, the rotor-side converter(RSC) has different control tasks for different periods of the grid fault. Firstly, for Period I, the RSC injects the demagnetizing current to ensure the controllability of the rotor voltage. Then, since the dc stator flux degenerates rapidly in Period II, the required demagnetizing current is low in Period II and the RSC uses the spare capacity to additionally generate the reactive(priority) and active current so that the transient voltage capability is corroborated and the DFIG also positively responds to the system frequency dynamic at the earliest time. Finally, a small amount of demagnetizing current is provided after the fault clearance. Most of the RSC capacity is used to inject the active current to further support the frequency recovery of the system. Simulations are carried out on a simple power system with a wind farm. Comparisons with other commonly used control methods are performed to validate the proposed control method. A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator(DFIG)equipped with a superconducting magnetic energy storage(SMES) device to enhance its transient voltage and frequency support capacity during grid faults. The SMES connected to the DC-link capacitor of the DFIG is controlled to regulate the transient dc-link voltage so that the whole capacity of the grid side converter(GSC) is dedicated to injecting reactive power to the grid for the transient voltage support. However, the rotor-side converter(RSC) has different control tasks for different periods of the grid fault. Firstly, for Period I, the RSC injects the demagnetizing current to ensure the controllability of the rotor voltage. Then, since the dc stator flux degenerates rapidly in Period II, the required demagnetizing current is low in Period II and the RSC uses the spare capacity to additionally generate the reactive(priority) and active current so that the transient voltage capability is corroborated and the DFIG also positively responds to the system frequency dynamic at the earliest time. Finally, a small amount of demagnetizing current is provided after the fault clearance. Most of the RSC capacity is used to inject the active current to further support the frequency recovery of the system. Simulations are carried out on a simple power system with a wind farm. Comparisons with other commonly used control methods are performed to validate the proposed control method.
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第7期52-63,共12页 中国物理B(英文版)
基金 supported by the National Natural Science Foundation of China(Grant No.51307124) the Major Program of the National Natural Science Foundation of China(Grant No.51190105)
关键词 doubly-fed induction generator transient rotor current control superconducting magnetic energy storage voltage support doubly-fed induction generator,transient rotor current control,superconducting magnetic energy storage,voltage support
  • 相关文献

参考文献38

  • 1Zhao H, Ma Y J and Liu S J 2011 Chin. Phys. B 20 12501.
  • 2Gholizadeh H, Hassannia A and Azarfar A 2012 Chin. Phys. B 21 010503.
  • 3Wei D Q and Luo X S 2008 Chin. Phys. B 17 92.
  • 4Messadi M, Mellit A and Kemih K 2015 Chin. Phys. B 24 010502.
  • 5Zheng G, Zou J X and Xu H B 2011 Acta Phys. Sin. 60 060506 (in Chinese).
  • 6Yu Y, Mi Z Q and Liu X J 2011 Acta Phys. Sin. 60 070509 (in Chinese).
  • 7Li D, Wang S L and Yang D 2010 Chin. Phys. B 19 010506.
  • 8Ren L N, Liu F C and Jiao X H 2012 Acta Phys. Sin. 61 060506 (in Chinese).
  • 9Yang G L and Li H G 2009 Acta Phys. Sin. 58 7552 (in Chinese).
  • 10Liu Y S, Farnell C, Balda J C and Mantooth H A 2015 Proceeding of IEEE Applied Power Electronics Conference and Exposition, March 15-19, 2015, Charlotte, USA, p. 697.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部