期刊文献+

650m^3高强钢氧气球罐检验与裂纹处理 被引量:1

Inspection and Crack Treatment for High Strength Steel 650 m^3 Oxygen Spherical Tank Treatment
下载PDF
导出
摘要 某钢铁企业650 m3氧气球罐在历次检验中发现对接焊缝上有较多的表面裂纹,针对该球罐主体材质07Mn Cr Mo VR高强钢的焊接特点,对裂纹部位进行复膜金相和硬度测定,从裂纹分布形貌和产生机理综合分析,认为属于焊接冷裂纹中的延迟裂纹,不属于再热裂纹,并提出相应处理和预防措施。 In several inspections for one 650 m3 oxygen spherical tank, quite a lot cracks were found in weld seams. With respect to the characteristics of welding for material of 07MnCrMoVR, the metallographic composition and the hardness around cracks were measured. Based on comprehensive analysis, it was considered that the cracks are postweld relayed cold cracks, and are not reheated cracks. Then, the related treating and protecting measures were presented.
出处 《化工设备与管道》 CAS 2015年第5期17-20,共4页 Process Equipment & Piping
关键词 高强钢 氧气球罐 检验 裂纹处理 high strength steel oxygen spherical tank inspection crack treatment
  • 相关文献

参考文献7

二级参考文献20

  • 1黄金祥,唐谱洪,赵保华.07MnCrMoVR钢制压力容器的两种焊接工艺及应用[J].中国化工装备,2009,11(4):27-29. 被引量:3
  • 2张亦良,程咏梅,姚希梦,吴如元,徐佩珠,王瑞礼.CF-62钢制1500m^3乙烯球罐焊接残余应力的现场测试[J].压力容器,1995,12(5):385-389. 被引量:1
  • 3《大型球罐用CF钢应用研究》课题组.CF-62钢焊接性试验研究[J].压力容器,1987,4(3):20-26.
  • 4朱振玉 等.用CF钢制造的5000m3和10000m3球罐实际性能[J].压力容器,1988,(6).
  • 5兰州石化公司.1500m3乙烯球罐安装过程的监造报告[R].合肥通用机械研究院,1998,(6)..
  • 6大庆石化公司.化工一厂1500m3乙烯球罐安全性分析报告[R].合肥通用机械研究所压力容器检验站,..
  • 7天津石化公司.石化二厂1000m3丙烯球罐残余应力测试报告[R].合肥通用机械研究所压力容器检验站,..
  • 8李敏.大型天然气球形容器长期运行的安全分析[A].第四届全国压力容器学术会议论文集.压力容器,1997,.
  • 9张亦良 等.10000m3天然气球罐的应力腐蚀和残余应力试验研究[A].第四届全国压力容器学术会议论文集.压力容器,1997,.
  • 10福建炼油化工有限公司.两台2000m3(G-2071、G-2073)丙烯球罐检验情况汇报[R].合肥通用机械研究所压力容器检验站,..